5-32
Problem Solving
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B45
System
Configuration Data
Write Error
Write error on the data configuring
the system.
Start the SETUP utility, execute [Advanced]
→
[Advanced]
→
[Reset Configuration
Data].
If the error persists, contact your service
representative to replace the riser card or
system I/O board.
0B46
ESMINT not
configured
Interrupt request for PCI board
and ESM are incorrect.
Start the SETUP utility, and specify the
correct value for [System Hardware]
→
[ESM IRQ] and [Advanced]
→
[PCI Device]
→
[PCI IRQ], then restart the server.
If the error persists, contact your service
representative to replace the I/O riser board
or system I/O board.
0B50
CPU #1 with error
taken off line.
Because an error was detected in
CPU #1, it was degraded.
0B51
CPU #2 with error
taken off line.
Because an error was detected in
CPU #2, it was degraded.
0B52
CPU #3 with error
taken off line.
Because an error was detected in
CPU #3, it was degraded.
0B53
CPU #4 with error
taken off line.
Because an error was detected in
CPU #4, it was degraded.
0B54
CPU #5 with error
taken off line.
Because an error was detected in
CPU #5, it was degraded.
0B55
CPU #6 with error
taken off line.
Because an error was detected in
CPU #6, it was degraded.
0B56
CPU #7 with error
taken off line.
Because an error was detected in
CPU #7, it was degraded.
0B57
CPU #8 with error
taken off line.
Because an error was detected in
CPU #8, it was degraded.
The displayed CPU is degraded. Contact
your service representative to replace the
failed CPU.
0B5F
Forced to use CPU
with error
CPU error is detected.
The system is started forcibly because
errors are detected on all CPUs. Contact
your service representative to replace the
CPU.
0B60
DIMM group #1 has
been disabled
A memory error was detected in
memory DIMM group #1. Memory
DIMM group #1 is degraded.
0B61
DIMM group #2 has
been disabled
A memory error was detected in
memory DIMM group #2. Memory
DIMM group #2 is degraded.
0B62
DIMM group #3 has
been disabled
A memory error was detected in
memory DIMM group #3. Memory
DIMM group #3 is degraded.
0B63
DIMM group #4 has
been disabled
A memory error was detected in
memory DIMM group #4. Memory
DIMM group #4 is degraded.
Contact your service representative to
replace the DIMM board.
Summary of Contents for Express5800/180Ra-7
Page 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 10: ...viii Contents ...
Page 94: ...3 28 Configuring Your System ...
Page 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Page 166: ...4 72 Upgrading Your System ...
Page 206: ...5 40 Problem Solving ...
Page 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Page 212: ...A 6 Specifications ...
Page 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 232: ...D 4 ROMPilot BIOS Error Codes ...
Page 242: ...10 Glossary ...
Page 246: ...4 Equipment Log ...
Page 250: ...Index 4 ...
Page 251: ...xx ...
Page 252: ... 456 01516 000 ...