Problem Solving 5-33
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B6F
DIMM group with
error is enabled
Memory error was detected.
The system is forcibly started because
errors are detected in all memory
devices. Contact your service
representative to replace the DIMM
boards.
0B70
The error occurred
during temperature
sensor reading
An error was detected in the
middle of detection of abnormal
temperature.
0B71
System Temperature
out of the range
Abnormal temperature was
detected.
0B74
The error occurred
during voltage
sensor reading
An error occurred during detection
of voltage.
0B75
System Voltage out
of the range
Abnormal system voltage was
detected.
0B78
The error occurred
during fan sensor
reading
An error was detected during read
of FAN sensor.
Contact your service representative to
replace the I/O riser board, or system
I/O board or baseboard.
0B7C
The error occurred
during the redundant
power module
confirmation
An error occurred while redundant
power supply was configured.
Contact your service representative to
replace the power unit.
0B80
BMC Memory Test
Failed.
BMC SRAM test error
0B81
BMC Firmware Code
Area CRC check
failed.
CRC error occurred in BMC code
area.
0B82
BMC core hardware
failure.
A firmware task cannot be ready
due to BMC hardware error.
0B90
BMC Platform
Information Area
Corrupted.
The platform information area of
BMC is damaged.
0B93
BMC SDR
Repository empty.
No BMC SDR data exists.
Contact your service representative to
replace the I/O riser board.
0B95
BMC FRU device
failure.
Access to SROM that contains the
chassis information failed.
Contact your service representative to
replace the baseboard.
0B96
BMC SDR
Repository failure.
Access to FMEM sector that
contains SDR information failed.
Contact your service representative to
replace the riser card.
0BA0
Address Array on
CPU Box #1 error
An error was detected in the
address area of the third cache for
the CPU backboard #1.
0BA1
Address Array on
CPU Box #2 error
An error was detected in the
address area of the third cache for
the CPU backboard #2.
0BA2
Data Array on CPU
Box #1 error
An error was detected in the data
area of the third cache for the
CPU backboard #1.
0BA3
Data Array on CPU
Box #2 error
An error was detected in the data
area of the third cache for the
CPU backboard #2.
Contact your service representative to
replace the CPU backboard.
Summary of Contents for Express5800/180Ra-7
Page 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 10: ...viii Contents ...
Page 94: ...3 28 Configuring Your System ...
Page 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Page 166: ...4 72 Upgrading Your System ...
Page 206: ...5 40 Problem Solving ...
Page 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Page 212: ...A 6 Specifications ...
Page 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 232: ...D 4 ROMPilot BIOS Error Codes ...
Page 242: ...10 Glossary ...
Page 246: ...4 Equipment Log ...
Page 250: ...Index 4 ...
Page 251: ...xx ...
Page 252: ... 456 01516 000 ...