1-26
System Overview
Automatic Rebuilding Function
The server supports the disk array automatic rebuilding function for data recovery.
Note:
The automatic rebuilding function supports a disk array
configuration of RAID levels, RAID1 or RAID5.
Rebuilding is to regenerate all data from a failed disk to a replacement disk. A rebuild is
necessary after a failed disk drive is replaced with a new one.
In disk array configuration RAID levels, RAID1 or RAID5 the failed disk does not
affect the operation. However, if another disk error occurs before automatic rebuilding,
the data may be destroyed. To prevent such an accident, it will rebuild after the failed
disk has been replaced.
In a conventional server, the user must select and execute automatic rebuilding using
various utilities. The server executes rebuilding automatically. Since the server also
supports hot-swapping function, the failed disk can be replaced while the power is on.
Observe the following when using an automatic rebuilding function.
!
Do not turn the power off. If power is turned off, automatic rebuilding will not start.
!
Use an interval of 60 seconds or more between mounting and dismounting the hard
disk drive.
!
If a hard disk is being rebuilt, do not replace the hard disk.
Expand Capacity Function
Disk pack capacity can be expanded by adding a disk drive while the system is running.
This function is only supported if the server is in the disk array configuration mode.
This function does not utilize operations such as data backup, pack reconfiguration,
initialization, restoring the data.
If a hard disk is added under the operation of the Global Array Manager, perform the
following.
!
After the hard disk is installed, wait for about 60 seconds and click the Scan Device
key. Clicking the Scan Device key after the execution of the expand array operation,
will display the added disk correctly.
Summary of Contents for Express5800/180Ra-7
Page 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Page 10: ...viii Contents ...
Page 94: ...3 28 Configuring Your System ...
Page 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Page 166: ...4 72 Upgrading Your System ...
Page 206: ...5 40 Problem Solving ...
Page 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Page 212: ...A 6 Specifications ...
Page 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 232: ...D 4 ROMPilot BIOS Error Codes ...
Page 242: ...10 Glossary ...
Page 246: ...4 Equipment Log ...
Page 250: ...Index 4 ...
Page 251: ...xx ...
Page 252: ... 456 01516 000 ...