Upgrading Your System 4-33
9.
Remove the ten screws (five on each side) that secure the profusion carrier
tray to the chassis (see Figure 4-21, A).
10.
Simultaneously rotate the eject/insert levers to eject the tray out of the
midplane. See Figure 4-21, B.
11.
Slide the tray out from the chassis. See Figure 4-21, C.
OM10709
C
A
A
B
B
A. Ten screws (five each side)
B. Eject/insert
levers
C. Slide the tray from the chassis
Figure 4-21. Removing the Profusion Carrier Tray
12.
Locate the four metal latch verification brackets located on each side of the
profusion carrier tray (two on each side). See Figure 4-22, B.
13.
To release the latches, pull up and out on each tab (see Figure 4-22, C) and
expose the four plastic mezzanine lock bars (two on each side).
14.
Release the plastic mezzanine lock bars by simultaneously squeezing the
winged protruding end of the lock bar and pulling out approximately a half
inch. See Figure 4-22, D.
Summary of Contents for Express5800/180Rb-7
Page 1: ... U s e r s G u i d e EXPRESS5800 180Rb 7 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e EXPRESS5800 180Rb 7 ...
Page 10: ...viii Contents ...
Page 58: ...2 24 Setting Up the System ...
Page 146: ...4 40 Upgrading Your System ...
Page 166: ...5 20 Problem Solving ...
Page 186: ...10 Glossary ...
Page 190: ...4 Equipment Log ...
Page 195: ...xx ...
Page 196: ... 456 01564 001 ...