Windows Setup and Operation 3-37
When you stop the operation of a CPU module, the indications of the status LEDs change as
follows. Below denotes that the only one CPU module is operating.
[Indications of status LEDs]
LED
CPU module 1
(Stopped)*
CPU module 2
(Operating)
1
CPU/IO module status LED1
Amber
-
2
CPU/IO module status LED2
-
Green blinking
3
DISK ACCESS LED
Green blinking
Green blinking
z
As an example, the indications of when CPU module 0 is stopped are shown.
3.
Press the start button of the CPU module stopped by ft server utility.
In the ft server utility, select the stopped CPU module and click [Up] of [Bring Up/Bring
Down].
Once the CPU module is started, hardware diagnosis and then synchronization of memory
(memory copy) are performed, and the duplication process is completed.
Note that the system is paused temporarily for copying memory during memory
synchronization.
[Indications of status LEDs during diagnosis]
LED
CPU module 0
(Started)
CPU module 1
(Operating)
1
CPU/IO module status LED1
-
-
2
CPU/IO module status LED2
-
Green blinking
3
DISK ACCESS LED
Green blinking
Green blinking
[Indications of status LEDs after completion of duplication]
LED
CPU module 0
(Operating)
CPU module 1
(Operating)
1
CPU/IO module status LED1
-
-
2
CPU/IO module status LED2
Green
Green
3
DISK ACCESS LED
Green blinking
Green blinking
IMPORTANT:
After duplication is completed, the status of memory will be checked.
Wait until this process ends to perform the next step (evaluation of start and stop of PCI
and CPU modules). When the process is complete, the following event log will be
output:
Source: srabid
Type: Information
Event ID:
4137
Description: Memory consistency check has completed memory scan.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......