7-18 Troubleshooting
Pop-up message of esmcmn.exe is displayed when starting the system:
→
The following pop-up message may be displayed when you restart the system which
NEC ESMPRO Agent is installed to and removal drives such as MO and
DVD-RAM are mounted on, without closing Windows Explorer, after displaying the
contents of media and removing the media by the software eject (by right-clicking
the DVD drive on Windows Explorer and selecting [Eject]) The message (the drive
name) displayed varies depeneding on the systems.
If the pop-up messages below are displayed, click [Cancel] or [Continue] to close
the dialog box. If you do not close the dialog box, you cannot start the Workstation
service and related services, causing unstable operation of the system. Also, if you
restart the system, execute it after terminating the program such as Windows
Explorer which displays a media.
<Example>
Memory dump (debug information) cannot be collected when a failure occurs:
Is there any available storage space on a storage location?
→
Specify the drive in which there is an available storage space of more than a
memory size on the server plus 12 MB (more than 2048 plus 12MB if a memory
size is more than 2GB).
For details, see “Set Memory Dump (Debug Information)” of “Step 14: Make
Settings for Failure Management” in Chapter 4 “Windows Setup” in the separate
User’s Guide for setup.
Is [Initial size] of the paging file of the OS partition smaller than [Recommended]?
→
If a value smaller than the [Recommended] value is set for [Initial Size] of the
paging file, accurate memory dump (debug information) may not be collected. Be
sure to create the file in the above size in the OS partition.
For details, see “Set Memory Dump (Debug Information)” of “Step 14: Make
Settings for Failure Management” in Chapter 4 “Windows Setup” in the separate
User’s Guide for setup.
Command prompt cannot be displayed in full screen:
In NEC Express5800/ft series
,
you cannot switch command prompt to full screen
mode. Also, you cannot execute applications that use command prompt full screen
mode. When you attempt to switch to full screen mode, the message below may
appear. Click [OK] and close the window.
<Example message>
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......