ESMPRO Agent for Linux 3-19
Network Hardware Error Percentage
- The percentage of network hardware
errors that were detected during the Sampling Interval. Hardware errors can
include packet collisions due to alignment errors or FCS errors. Errors may also
occur when the network cables are not securely fastened or the HUB power is
not turned on.
Transmission Retry Percentage
- The number of collision errors as a
percentage of all transmitted packets during the Sampling Interval. Errors here
may indicate that the network traffic is extremely heavy. You might try reducing
the network traffic to this server.
Transmission Abort Percentage
- The percentage of packets discarded due to
excess collisions. Errors here may indicate that the network traffic is extremely
heavy. Try reducing the network traffic to this server.
Temperature Properties
Temperature is measured by hardware thermal sensors. On the Temperature tab,
set temperature limits and reset values that determine the status of the Agent and
generate alert messages. Temperature status is displayed in the Enclosure folder
in the Data Viewer. You can also set temperature limits and reset values there as
well.
Thermal sensor
- The location of the temperature sensor
Enable threshold
- Check this box to make these settings effective now. Leave
it unchecked to store settings for future use. Thresholds can also be set in the
Data Viewer at the ESMPRO Manager.
Fatal high/report -
(fatal high limit) When the temperature exceeds this value,
a fatal alert message is generated and the status of the Agent changes to
abnormal. The fatal high limit must meet the following conditions: