Monitoring the ft Server 4-31
5.
Enter the directory in which the updated firmware image is located (Step 1).
After you have entered the absolute path of the firmware image, click on the
Execute
button to update the firmware. The “Firmware update completed”
screen displays when the update has completed.
CAUTION
At this point in the firmware update procedure, each CPU
module may be at different revision levels. Perform Step 6
immediately after confirmation that the firmware update has
completed in Step 5.
6.
At the FT Server Utility screen, select CPU module 2. Click on the
Firmware Update
button. The Firmware Update screen displays.
7.
Enter the directory in which the updated firmware image is located (Step 1).
After you have entered the absolute path of the firmware image, click on
Execute
to update the firmware. The “Firmware update completed” screen
displays when the update has completed.
8.
Bring up CPU module 2. The firmware in both CPU modules has been
updated and both CPU modules are up.
Execute Button
Pressing the
Execute
button dumps the current memory contents to a log file.
Information in this log file may be used during troubleshooting procedures. A
memory dump can be made with the CPU module up or down. However, if a
memory dump is made when the CPU module up, The CPU module is taken
offline until the memory dump has completed.
Note:
In the following procedure a memory dump of
CPU module 1 will be performed.