Troubleshooting 7-7
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
Cor1 +3.3vAlm
02
Amber
Lit
PCI module #2
Fatal
3.3
-V power voltage
alarm (lower limit)
Cor1 +3.3vAlm
07
Amber Blink PCI module #2
3.3
-V power voltage alarm
(upper limit)
Cor1 +3.3vAlm
09
Amber
Lit
PCI module #2
Fatal
3.3
-V power voltage
alarm (upper limit)
Cor1 +3.3vsAlm
00
Amber Blink PCI module #2
3.3
-V power voltage alarm
(lower limit)
Cor1 +3.3vsAlm
02
Amber
Lit
PCI module #2
Fatal
3.3
-V power voltage
alarm (lower limit)
Cor1 +3.3vsAlm
07
Amber Blink PCI module #2
3.3
-V power voltage alarm
(upper limit)
Cor1 +3.3vsAlm
09
Amber
Lit
PCI module #2
Fatal
3.3
-V power voltage
alarm (upper limit)
Cor1 +5.0vAlm
00
Amber Blink PCI module #2
5
-V power voltage alarm
(lower limit)
Cor1 +5.0vAlm
02
Amber
Lit
PCI module #2
Fatal
5
-V power voltage alarm
(lower limit)
Cor1 +5.0vAlm
07
Amber Blink PCI module #2
5
-V power voltage alarm
(upper limit)
Cor1 +5.0vAlm
09
Amber
Lit
PCI module #2
Fatal
5
-V power voltage alarm
(upper limit)
Cor1 +5.0vsAlm
00
Amber Blink PCI module #2
5
-V power voltage alarm
(lower limit)
Cor1 +5.0vsAlm
02
Amber
Lit
PCI module #2
Fatal
5
-V power voltage alarm
(lower limit)
Cor1 +5.0vsAlm
07
Amber Blink PCI module #2
5
-V power voltage alarm
(upper limit)
Cor1 +5.0vsAlm
09
Amber
Lit
PCI module #2
Fatal
5
-V power voltage alarm
(upper limit)
Cor1 -12vAlm 00
Amber Blink PCI module #2
-12-V power voltage alarm
(lower limit)
Cor1 -12vAlm 02
Amber
Lit
PCI module #2
Fatal -12-V power voltage
alarm (lower limit)
Cor1 -12vAlm 07
Amber Blink PCI module #2
-12-V power voltage alarm
(upper limit)
Cor1 -12vAlm 09
Amber
Lit
PCI module #2
Fatal -12-V power voltage
alarm (upper limit)
Cor1 Bus PERR 01
Green
Blink PCI module #2
PCI bus parity error
Cor1 Bus SERR 01
Green
Blink PCI module #2
Fatal PCI bus error
Cor1 CLK Alm 00
Amber Blink CLOCK
board
Clock
alarm (lower limit)
Cor1 CLK Alm 02
Amber
Lit CLOCK
board
Fatal Clock
alarm (lower
limit)
Cor1 CLK Alm 07
Amber Blink CLOCK
board
Clock
alarm (upper limit)
Cor1 CLK Alm 09
Amber
Lit CLOCK
board
Fatal Clock
alarm (upper
limit)
Contact your sales
agent.
Cor1 FAN Alm 01
Amber Blink PCI module #2
Cooling fan1 alarm
Cor1 FAN Alm 02
Amber Blink PCI module #2
Cooling fan2 alarm
Cor1 FAN Alm 03
Amber Blink PCI module #2
Cooling fan3 alarm
Cor1 FAN Alm 04
Amber Blink PCI module #2
Cooling fan4 alarm
Cor1 FAN Alm 05
Amber Blink PCI module #2
Cooling fan5 alarm
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...