7-10 Troubleshooting
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
CPU0 FAN Alm 01
Amber Blink CPU module #1
Cooling fan1 alarm
CPU0 FAN Alm 03
Amber Blink CPU module #1
Cooling fan2 alarm
CPU0 FAN Alm 04
Amber Blink CPU module #1
Cooling fan3 alarm
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If
not solved by the above,
contact your sales agent.
CPU0 offline
Green
Blink CPU module #1
PCI module logically isolated
Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
CPU0 removed
Green
Blink CPU module #1
PCI module detached
Dismount and remount the
PCI module. If not
solved by the above,
contact your sales agent.
CPU0 Temp Alm 00
Amber Blink CPU module #1
Temperature alarm (lower limit)
CPU0 Temp Alm 02
Amber
Lit
CPU module #1 Fatal temperature alarm (lower
limit)
CPU0 Temp Alm 07
Amber Blink CPU module #1
Temperature alarm (upper limit)
CPU0 Temp Alm 09
Amber
Lit
CPU module #1
Fatal temperature alarm (upper
limit)
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If
not solved by the above,
contact your sales agent.
CPU0 VccpAlm 00
Amber Blink CPU module #1
CPU operating voltage alarm
(lower limit) (VCCP)
CPU0 VccpAlm 02
Amber
Lit
CPU module #1
Fatal CPU operating voltage
alarm (lower limit) (VCCP)
CPU0 VccpAlm 07
Amber Blink CPU module #1
CPU operating voltage alarm
(upper limit) (VCCP)
CPU0 VccpAlm 09
Amber
Lit
CPU module #1
Fatal CPU operating voltage
alarm (upper limit) (VCCP)
CPU0 Vtt Alm 00
Amber Blink CPU module #1
1.25-V power voltage alarm
(lower limit)
CPU0 Vtt Alm 02
Amber
Lit
CPU module #1
Fatal 1.25-V power voltage
alarm (lower limit)
CPU0 Vtt Alm 07
Amber Blink CPU module #1
1.25-V power voltage alarm
(upper limit)
CPU0 Vtt Alm 09
Amber
Lit
CPU module #1
Fatal 1.25-V power voltage
alarm (upper limit)
Contact your sales agent.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...