Troubleshooting 7-11
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
CPU00 Temp Alm
00
Amber Blink CPU module #1
CPU#1 temperature alarm
(lower limit)
CPU00 Temp Alm
02
Amber
Lit
CPU module #1
CPU#1fatal temperature alarm
(lower limit)
CPU00 Temp Alm
07
Amber Blink CPU module #1
CPU#1temperature alarm
(upper limit)
CPU00 Temp Alm
09
Amber
Lit
CPU module #1
CPU#1 fatal temperature
alarm (upper limit)
CPU01 Temp Alm
00
Amber Blink CPU module #1
CPU#2 temperature alarm
(lower limit)
CPU01 Temp Alm
02
Amber
Lit
CPU module #1
CPU#2 fatal temperature
alarm (lower limit)
CPU01 Temp Alm
07
Amber Blink CPU module #1
CPU#2 temperature alarm
(upper limit)
CPU01 Temp Alm
09
Amber
Lit
CPU module #1
CPU#2 fatal temperature
alarm (upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
CPU2 +12ss Alm
00
Amber
Blink
CPU module #2
12-V power voltage alarm
(lower limit)
Contact your sales
agent.
CPU2 +12ss Alm
02
Amber Lit
CPU module #2
Fatal 12-V power voltage
alarm (lower limit)
CPU2 +12ss Alm
07
Amber Blink CPU module #2
12-V power voltage alarm
(upper limit)
CPU2 +12ss Alm
09
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (upper limit)
CPU2 +12v Alm 00
Amber Blink CPU module #2
12-V power voltage alarm
(lower limit)
CPU2 +12v Alm 02
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (lower limit)
CPU2 +12v Alm 07
Amber Blink CPU module #2
12-V power voltage alarm
(upper limit)
CPU2 +12v Alm 09
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (upper limit)
CPU2 +1.5vAlm
00
Amber Blink CPU module #2
1.5-V power voltage alarm
(lower limit)
CPU2 +1.5vAlm
02
Amber
Lit
CPU module #2
Fatal 1.5-V power voltage
alarm (lower limit)
CPU2 +1.5vAlm
07
Amber Blink CPU module #2
1.5-V power voltage alarm
(upper limit)
CPU2 +1.5vAlm
09
Amber
Lit
CPU module #2
Fatal 1.5-V power voltage
alarm (upper limit)
Contact your sales
agent.
CPU2 +2.5vAlm
00
Amber Blink CPU module #2
2.5-V power voltage alarm
(lower limit)
CPU2 +2.5vAlm
02
Amber
Lit
CPU module #2
Fatal 2.5-V power voltage
alarm (lower limit)
CPU2 +2.5vAlm
07
Amber Blink CPU module #2
2.5-V power voltage alarm
(upper limit)
CPU2 +2.5vAlm
09
Amber
Lit
CPU module #2
Fatal 2.5-V power voltage
alarm (upper limit)
Contact your sales
agent.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...