7-12 Troubleshooting
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
CPU2 +2.5VcAlm
00
Amber Blink CPU module #2 2.5-V power voltage alarm
(lower limit)
CPU2 +2.5VcAlm
02
Amber
Lit
CPU module #2 Fatal 2.5-V power voltage
alarm (lower limit)
CPU2 +2.5VcAlm
07
Amber Blink CPU module #2 2.5-V power voltage alarm
(upper limit)
CPU2 +2.5VcAlm
09
Amber
Lit
CPU module #2 Fatal 2.5-V power voltage
alarm (upper limit)
CPU2 +3.3vAlm
00
Amber Blink CPU module #2
3.3
-V power voltage alarm
(lower limit)
CPU2 +3.3vAlm
02
Amber
Lit
CPU module #2 Fatal
3.3
-V power voltage
alarm (lower limit)
CPU2 +3.3vAlm
07
Amber Blink CPU module #2
3.3
-V power voltage alarm
(upper limit)
CPU2 +3.3vAlm
09
Amber
Lit
CPU module #2 Fatal
3.3
-V power voltage
alarm (upper limit)
CPU2 +3.3vsAlm
00
Amber Blink CPU module #2
3.3
-V power voltage alarm
(lower limit)
CPU2 +3.3vsAlm
02
Amber
Lit
CPU module #2 Fatal
3.3
-V power voltage
alarm (lower limit)
CPU2 +3.3vsAlm
07
Amber Blink CPU module #2
3.3
-V power voltage alarm
(upper limit)
CPU2 +3.3vsAlm
09
Amber
Lit
CPU module #2 Fatal
3.3
-V power voltage
alarm (upper limit)
CPU2 +5.0vAlm
00
Amber Blink CPU module #2 5-V power voltage alarm
(lower limit)
CPU2 +5.0vAlm
02
Amber
Lit
CPU module #2 Fatal 5-V power voltage alarm
(lower limit)
CPU2 +5.0vAlm
07
Amber Blink CPU module #2 5-V power voltage alarm
(upper limit)
CPU2 +5.0vAlm
09
Amber
Lit
CPU module #2 Fatal 5-V power voltage alarm
(upper limit)
CPU2
+5.0vsAlm00
Amber Blink CPU module #2 5-V power voltage alarm
(lower limit)
CPU2
+5.0vsAlm02
Amber
Lit
CPU module #2 Fatal 5-V power voltage alarm
(lower limit)
CPU2
+5.0vsAlm07
Amber Blink CPU module #2 5-V power voltage alarm
(upper limit)
CPU2
+5.0vsAlm09
Amber
Lit
CPU module #2 Fatal 5-V power voltage alarm
(upper limit)
CPU2 broken
Green
Blink CPU module #2 CPU module breakdown
Contact your sales
agent.
CPU2 FAN Alm 01
Amber Blink CPU module #2 Cooling fan 1 alarm
CPU2 FAN Alm 03
Amber Blink CPU module #2 Cooling fan 2 alarm
CPU2 FAN Alm 04
Amber Blink CPU module #2 Cooling fan 3 alarm
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...