Troubleshooting 7-13
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
CPU2 offline
Green Blink CPU module #2
The CPU module has been
logically disconnected.
Start the PCI module by
ft sever utility or
dismount and remount
that module. If not
solved by the above,
contact your sales
agent.
CPU2 removed
Green Blink CPU module #2
The CPU module has come
off.
Dismount and remount
the PCI module. If not
solved by the above,
contact your sales
agent.
CPU2 Temp Alm 00
Amber Blink CPU module #2
Temperature alarm (lower
limit)
CPU2 Temp Alm 02
Amber Lit
CPU module #2
Fatal temperature alarm
(lower limit)
CPU2 Temp Alm 07
Amber Blink CPU module #2
Temperature alarm (upper
limit)
CPU2 Temp Alm 09
Amber Lit
CPU module #2
Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
CPU2 VccpAlm 00
Amber Blink CPU module #2
CPU operating voltage alarm
(lower limit) (VCCP)
CPU2 VccpAlm 02
Amber Lit
CPU module #2
Fatal CPU operating voltage
alarm (lower limit) (VCCP)
CPU2 VccpAlm 07
Amber Blink CPU module #2
CPU operating voltage alarm
(upper limit) (VCCP)
CPU2 VccpAlm 09
Amber Lit
CPU module #2
Fatal CPU operating voltage
alarm (upper limit) (VCCP)
CPU2 VttAlm 00
Amber Blink CPU module #2
1.25-V power voltage alarm
(lower limit)
CPU2 VttAlm 02
Amber Lit
CPU module #2
Fatal 1.25-V power voltage
alarm (lower limit)
CPU2 VttAlm 07
Amber Blink CPU module #2
1.25-V power voltage alarm
(upper limit)
CPU2 VttAlm 09
Amber Lit
CPU module #2
Fatal 1.25-V power voltage
alarm (upper limit)
Contact your sales
agent.
CPU20 TempAlm
00
Amber Blink CPU module #2
CPU#1 temperature alarm
(lower limit)
CPU20 TempAlm
02
Amber Lit
CPU module #2
Fatal CPU#1 temperature
alarm (lower limit)
CPU20 TempAlm
07
Amber Blink CPU module #2
CPU#1 temperature alarm
(upper limit)
CPU20 TempAlm
09
Amber Lit
CPU module #2
Fatal CPU#1 temperature
alarm (upper limit)
CPU21 TempAlm
00
Amber Blink CPU module #2
CPU#2 temperature alarm
(lower limit)
CPU21 TempAlm
02
Amber Lit
CPU module #2
Fatal CPU#2 temperature
alarm (lower limit)
CPU21 TempAlm
07
Amber Blink CPU module #2
CPU#2 temperature alarm
(upper limit)
CPU21 TempAlm
09
Amber Lit
CPU module #2
Fatal CPU#2 temperature
alarm (upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...