Troubleshooting 7-15
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive error
TIPS:
For error messages on optional SCSI controller board and disk
array controller, refer to the manual provided with those options.
On-screen error message
Cause
Action
0200 Failure Fixed Disk
•
Configuration error in Setup
menu.
•
Hard disk is faulty.
•
CPU module board is faulty.
•
PCI module board is faulty.
•
Check configuration in Setup
menu.
•
Replace the hard disk.
•
Replace the CPU module
board.
•
Replace the PCI module
board.
0210 Stuck Key
Keyboard connection error
•
Disconnect the keyboard
and connect it back again.
•
Replace the keyboard.
•
Replace the PCI module
board.
0211 Keyboard error
Keyboard is faulty.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
•
Check the keyboard
connection.
•
Restart the server.
•
Replace the PCI module
board.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked.
Unlock the key switch.
0220 Monitor type does not
match CMOS - Run
SETUP
Illegal monitor type is
specified.
•
Select "Get Default Value"
from the Setup menu.
•
Clear the CMOS data.
0230 System RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU module
board.
0231 Shadow RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU module
board.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...