Troubleshooting 7-17
On-screen error message
Cause
Action
0B29 Unsupported Processor
detected on Processor 2
The processor (CPU) not
supported by this server is
installed in Processor 2.
Install the CPU appropriate to
the server.
0B30 CPU FAN #1 Alarm
occurred
0B31 CPU FAN #2 Alarm
occurred
•
Dusts are clogged in fan.
•
Fan is faulty.
•
CPU module board is faulty.
•
Replace the fan.
•
Replace the CPU module
board.
•
Connect fan cable properly.
0B32 CPU FAN #3 Alarm
occurred
•
Dusts are clogged in fan.
•
Fan is faulty.
•
PCI module board is faulty.
•
Replace the fan.
•
Replace the PCI module
board.
•
Connect fan cable properly.
0B40 Invalid System
Configuration Data
•
Configuration error in
SETUP.
•
CPU/PCI module board is
faulty.
•
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
•
Replace the CPU/PCI
module board.
0B41 System Configuration
Data Read error
•
Configuration error in
SETUP.
•
CPU/PCI module board is
faulty.
•
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
•
Replace the CPU/PCI
module board.
0B42 Resource Conflict
Configuration error in SETUP.
Correct device configuration in
SETUP
0B43 Warning: IRQ not
configured
Configuration error in SETUP.
Correct settings in SETUP
0B44 Expansion Rom not
initialized
Configuration error in SETUP.
In SETUP, disable
decompression of expansion
ROM on unnecessary optional
PCI cards.
0B45 System Configuration
Data Write error
•
Configuration error in
SETUP.
•
CPU/PCI module board is
faulty.
•
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
•
Replace the CPU/PCI
module board.
0B47 Missing date and time
synchronization
The date and time are
incorrect due to a
communication error between
BMCs.
•
Restart the system.
•
Re-set the date and time in
SETUP.
If the error persists, replace the
PCI module board.
0B49 BMC Issued Reset
Command, but failed
System Reset
•
System cannot be reset by
BMC’s reset command.
Replace PCI module board.
0B6E DIMMs are installed out
of order
•
DIMM is faulty.
Replace DIMM.
0B70 The error occurred
during temperature
sensor reading
•
SMBus device is faulty.
•
SMBus is faulty.
Replace the CPU/PCI module
or back panel board.
0B71 System temperature out
of Range
•
Ambient temperature is out
of range.
•
Fan is faulty.
•
CPU/PCI module board is
faulty.
•
Check the setting in SETUP
•
Clean the fan.
•
Replace the fan.
•
Replace the CPU/PCI
module board.
Summary of Contents for Express5800/320Lb FT Linux
Page 10: ...iv This page is intentionally left blank ...
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Page 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Page 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Page 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Page 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Page 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Page 70: ...2 34 General Description This page is intentionally left blank ...
Page 118: ...3 48 Setup This page is intentionally left blank ...
Page 162: ...4 44 System Configuration This page is intentionally left blank ...
Page 294: ...6 14 Maintenance This page is intentionally left blank ...
Page 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Page 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Page 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Page 410: ...8 74 System Upgrade This page is intentionally left blank ...
Page 412: ...A 2 Specifications This page is intentionally left blank ...