Copyright Notice and Liability Disclaimer 

The information contained herein is subject to change without notice. 

Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in 
the United States and/or other countries   

Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in 
the United States and other countries. 

Linux is a trademark of Linus Torvalds. 

Red Hat is a registered trademark of Red Hat, Inc. in the U.S. 

All other products, brands, or trade names used in this document are trademarks or registered trademarks 
of their respective holders. 

NEC shall not be liable for technical or editorial errors or omissions contained herein. 

For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. 

The USB interface is not guaranteed to work properly for all USB devices. 

 

Summary of Contents for Express5800/GT110e-S

Page 1: ...ing model Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server July 17 2013 Revision 5 0 NEC Corporation ...

Page 2: ...ion 12 4 2 3 5 inch Drive Configuration 14 4 3 2 5 inch Drive Configuration 16 5 Internal Optical Drive 27 6 Internal RDX Drive 27 7 PCI Card 28 7 1 Network Interface Controller 28 7 2 Serial Port Adapter 28 8 Other Add in Components 29 8 1 Internal Flash Memory 29 8 2 Flash FDD 29 8 3 Input Devices 29 9 Add on Components 30 9 1 Server Management License 30 9 2 Dust Insect Proof Kit 30 9 3 Medium ...

Page 3: ...M Standard Capacity 0 GB Maximum Capacity 32 GB 4 x 8 GB Internal Storage Standard Capacity 0 GB Maximum Capacity 8 TB 2 x 4 TB Disk Controller SATA 6Gb s Integrated RAID SATA 1 RAID 0 1 Hot Plug Optical Disk Drive DVD ROM 3 5 inch Media Bays 1 Disk Drive Bays 2 Expansion Slots Total 4 slots available 1 PCIe 3 0 2 x16 x16 connector 2 PCIe 2 0 x4 x8 connector 1 32 bit 33 MHz PCI Video Controller VR...

Page 4: ... Windows Server 2008 Enterprise x64 Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2012 Standard 5 Microsoft Windows Server 2012 Datacenter 5 Red Hat Enterprise Linux 5 8 or later 6 Red Hat Enterprise Linux 5 8 or later EM64T 6 Red Hat Enterprise Linux 6 2 or later 6 Red Hat Enterprise Linux 6 2 or later EM64T 6 VMware ESXi 5 0 update...

Page 5: ...inch Media Bays 1 Disk Drive Bays 3 to 5 1 Expansion Slots Total 4 slots available 1 PCIe 3 0 3 x16 x16 connector 2 PCIe 2 0 x4 x8 connector 1 32 bit 33 MHz PCI Video Controller VRAM Integrated in Server Management Controller 32MB Resolution Color 1280 x 1024 16 7M 4 Interfaces 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 8 USB2 0 2 front 4 rear 2 internal 2 10...

Page 6: ... 6 Red Hat Enterprise Linux 5 8 or later EM64T 6 Red Hat Enterprise Linux 6 2 or later 6 Red Hat Enterprise Linux 6 2 or later EM64T 6 VMware ESXi 5 0 update 1 7 VMware ESXi 5 1 7 1 An optional HDD Cage is required to install more than 3 hard drives The optional HDD Cage occupies 3 5 inch media bay 2 Embedded SATA RAID controller is supported only on Windows operating systems 3 The PCIe x16 slot w...

Page 7: ...ctors B Power Button G Optical Disk Drive C Power LED H 3 5 inch Media Bay D Hard Drive Activity LED I 2 5 inch Drive Bay E System Status LED J Drive Bay Cover Key Rear Views Leged A Serial Port Connector F Management LAN Connector B VGA Connector G Data LAN Connectors C BMC Reset Switch H PCI Slots Low Profile D Dump NMI Switch I AC Inlet E USB Connectors A B C D E F G H A B C D E F G H I J A B C...

Page 8: ...CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model NEC Corporation Revision 5 0 July 17 2013 8 Dimensions mm Tower installation Lay flat installation ...

Page 9: ...4 DIMM 1 DIMM 3 5 inch Drive Cage Optical Drive Media Bay PCI 2 PCI 3 PCI 4 PCIe 2 0 Power Supply PCI BBU slot PCIe 3 0 or 2 0 Media Bay Processor CHASSIS INSIDE CHASSIS FRONT CHASSIS REAR Power Supply Cooling FAN Cooling FAN Cooling FAN 2 5 inch Drive Cage PCI 1 Optical Drive 4 DIMM 1 DIMM Optical Drive Media Bay PCI 2 PCI 3 PCI 4 PCIe 2 0 Power Supply PCI BBU slot PCIe 3 0 or 2 0 Media Bay 2 5 i...

Page 10: ...egend 1 PCIe 2 0 x4 x8 connector Low Profile up to 167 6mm length 2 PCIe 2 0 x4 x8 connector Low Profile up to 167 6mm length 3 PCIe 3 0 or 2 0 x16 x16 connector Low Profile up to 167 6mm length 4 32 bit 33 MHz 5 V PCI Low Profile up to 167 6mm length NOTE The slot 3 works at PCIe 3 0 speeds on Xeon processor systems 4 3 2 1 ...

Page 11: ...ry Product Name Description Part Number Processors Required Processor Kit 2C G2020 Intel Pentium Processor G2020 2 90 GHz 2C 2T 3 MB N8101 637F Processor Kit 4C E3 1220v2 Intel Xeon Processor E3 1220v2 3 10 GHz 4C 4T 8 MB N8101 587F NOTE One processor kit from above must be installed 3 Memory Available slots 4 Product Name Description Part Number 2GB DDR3 1600 UNB Memory Kit 2GB Unbuffered ECC DIM...

Page 12: ...2 GB Microsoft Windows Server 2003 R2 Enterprise x64 Edition 1 TB 32 GB Microsoft Windows Server 2008 Enterprise x64 Microsoft Windows Server 2008 R2 Enterprise 2 TB 32 GB Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter 4 TB 32 GB Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 16 GB 16 GB Red Hat Enterprise Linux 5 EM64T 1 TB 32 GB Red Hat Enterprise Linux 6 ...

Page 13: ...e same system is not supported All hard drives within a system should be of the same rotation speed Hot plug insertion removal is not supported with the embedded SATA non RAID controller Non RAID RAID 5 128 MB Cache 1GB Cache Battery 512 MB Cache Refer to 4 3 1 Refer to 4 3 3 Refer to 4 3 5 Refer to 4 3 6 RAID 0 1 SATA SAS SATA SAS SATA SAS SATA Available Interface Embedded SATA RAID Controller Op...

Page 14: ...oduct Name Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb s SATA RAID 0 1 capable Standard Cable Internal SATA Cable Single SATA to Single SATA 2 sets Standard HDD Cage 3 5 inch Drive Cage 2 x 3 5 inch non hot plug fixed hard drive bays Standard Drive 2 slots available 500GB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 359 1TB 7...

Page 15: ...SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 362 NOTE All hard drives within a RAID array should be of the same capacity 4 2 4 RAID 0 1 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller Required RAID Controller 512MB RAID 0 1 LSI MegaRAID SAS 9267 8i RAID 0 1 512 MB Int 8 PCIe 2 0 x8 SAS 6Gb s SATA 6Gb s N8103 149 RAID BBU Recommended RAID Battery Backup Unit...

Page 16: ...plug insertion removal is not supported with the embedded SATA non RAID controller 4 3 2 Embedded SATA RAID Controller Category Product Name Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb s SATA 2x 3Gb s SATA RAID 0 1 capable Standard Cable Required Internal SATA Cable 3x Single SATA to mini SAS K410 241 00 Drive Cage 2 5 inch Drive Cage 3 x 2 5 inch hot plug hard drive...

Page 17: ... HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 302 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6G...

Page 18: ... 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 302 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s ...

Page 19: ... 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 302 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s ...

Page 20: ... HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 322 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s...

Page 21: ...00GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 302 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 303 300GB 15K Hot Plug 2 5 inch SAS HDD ...

Page 22: ...B SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 322 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8...

Page 23: ...S HDD 2 5 inch 6Gb s 10 000 rpm N8150 322 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 ...

Page 24: ... SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 322 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N81...

Page 25: ...SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 301 450GB 10K Hot Plug 2 5 inch SAS HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 322 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150...

Page 26: ...2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 304 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 332 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 408 73 2GB 15K Hot Plug 2 5 inch SAS HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 302 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD...

Page 27: ...SB port or 1 x pin header for front panel USB Standard Cable Required Internal USB Cable 1x Internal USB to 1x USB device NOTE The cable is required to install USB tape drive only K410 255 00 Internal USB Cable 1x pin header for front panel USB to 1x USB device and 1x front panel USB port NOTE The cable is required to install internal flash memory and USB tape drive A USB tape drive occupies one f...

Page 28: ...d Linux support teaming with bonding function supported by OS Network Interface Team OS GbE LAN controller Embedded 1GbE NIC and N8104 138 132 Up to four teams per one system Up to four ports per one team Windows Server 2003 R2 Windows Server 2008 Windows Server 2008 R2 Window Server 2012 Red Hat Linux Using iSCSI See the table below for supported network interfaces and OS combinations Category Ne...

Page 29: ...he flash memory Installation of Windows server with express setup Installation of Starter Pack the package of NEC qualified drivers and system setting tools Installation of NEC ESMPRO Agent and Universal RAID Utility Performance of the Test and Diagnosis Tool N8115 05 8 2 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive Product Name Description Part Nu...

Page 30: ...Remote media Enables the user to use the CD DVD FD Flash memory of the remote terminals PC server as if accessing the local drives N8115 04 NOTE Remote KVM and remote media features are not available for virtual machines 9 2 Dust Insect Proof Kit The server supports the dust resistant feature Choose the following kit to install the system in dusty places Category Product Name Description Part Numb...

Page 31: ...ole 2 5 GUI based screen OS console Remote control via LAN Remote reset power on off dump Remote Power Capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 3 3 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS 3 3 Maintenance EXPRESSSCOPE Profile key Backup resto...

Page 32: ...ID Controller 512MB RAID 0 1 N8103 150 RAID Controller 512MB RAID 0 1 5 6 N8103 151 RAID Controller 1GB RAID 0 1 5 6 N8103 167 RAID Controller 1GB RAID 0 1 5 6 N8104 138 1000BASE T Adapter 1ch N8104 132 1000BASE T Adapter 2ch Supported PCI cards and Installable Slots Slots Part Number Product Name 1 2 3 4 N8103 128 RAID Controller 128MB RAID 0 1 N8103 149 RAID Controller 512MB RAID 0 1 N8103 150 R...

Page 33: ...stered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial error...

Page 34: ...N8153 02 RDX Cartridge 1TB N8153 03 Discontinued products removed Processor Kit 2C G640 N8101 586F 100GB SSD N8150 709 400GB SSD N8150 710 Others Remove Internal DAT USB N8151 69A Support NIC teaming on Windows Server 2012 systems 3 0 December 21 2012 Part number changed Internal DAT USB N8151 69A Others Add Windows Server 2012 to the list of operating system supported Support N8103 167 RAID Contr...