1. POST Error Message
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
193
Chapter 3 Appendix
(4/5)
Error Message
Description
Action
C065
5th SMBus device Error
detected.
An error occurred in the 5th SM
Bus.
Contact your sales representative.
C066
6th SMBus device Error
detected.
An error occurred in for the 6th SM
Bus.
C067
7th SMBus device Error
detected.
An error occurred in the 7th SM
Bus.
C068
8th SMBus device Error
detected.
An error occurred in the 8th SM
Bus.
C103
BMC core hardware failure.
BMC device (chip) error
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C104
BMC IBF or OBF check failed.
Accessing the BMC address
failed.
C105
BMC SEL area full.
No memory to write the system
event log.
Run Offline Tools by pressing <F4> key and
delete the event logs.
C10B
BMC operational code
corrupted.
BMC device (chip) error
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
Chassis information is incorrect.
C10E
BMC SDR Repository empty.
BMC device (chip) error
C10F
IPMB signal lines do not
respond.
SMC (Satellite Management
Controller) failure
C110
BMC FRU device failure.
Failure of the SROM for storing
chassis information
C111
BMC SDR Repository failure.
Failure of the SROM for storing
sensor data record information
C112
BMC SEL device failure.
BMC device (chip) failure
C113
BMC RAM test error.
BMC RAM error
C114
BMC Fatal hardware error.
BMC error
C115
Management controller not
responding
Management controller does not
respond.
Update the BMC firmware.
C116
Private I2C bus not
Responding.
Private I2C bus does not respond. Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A SEL
corrupt.
BMC error or illegal system event
log data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
mounted.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
BMC Mezzanine partition is
invalid.
C11D
BMC is in Forced Boot Mode.
The Forced Boot Mode of BMC
was detected.
Check the jumper switch on the motherboard.
Unplug the power cable, wait for at least 30
seconds, and then restart the server.
C11E
Communication with BMC was
failed in previous boot.
Communication with BMC was
failed in previous boot.
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.
C120
BMC Runtime FW corrupted.
An error occurred on BMC
Runtime FW.
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C121
BMC Force Update FW
corrupted.
An error occurred on BMC Force
Update FW.
C122
BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123
BMC eMMC inaccessible.
Failed to access to BMC eMMC.
C125
BMC eMMC mode error.
BMC eMMC mode error.
C126
BMC eMMC partition
corrupted.
An error occurred on BMC eMMC
partition.