CONFIGURATION GUIDE
–
NEC Express5800R120d-1M
NEC Corporation
Revision 7.0
– July 17, 2013
20
4.2.5 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9265CV-8i (with CV)
RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8),
6Gb/s, flash cache protection modules included
N8103-152
SSD Caching
Recommended
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
-
SSD used for cache is required.
-
The SSD capacity which can be used as Read Cache is up
to 512 GB.
N8103-156
Cable
Internal SAS/SATA Cable
1 x mini-SAS to 1 x mini-SAS, 2 sets
K410-271(00)
HDD Cage
2.5-inch HDD Cage
6 x 2.5-inch hot plug hard drive bays
(Standard)
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
73.2GB HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-302
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives can be mixed in one system
For SAS and SATA hard drive mix configuration, they must be installed in separate drive groups with
multiple of two drives.
A large-capacity RAID array configuration requires long-time rebuilding when to recover from the
failure. In order to improve the reliability, RAID 6 or RAID 60 cofiguration, which supports two hard
drives failures, is recommended as the redundancy becomes invalid during the system recovery.
For VMware ESXi 5.x installation, to download the CIM provider is required.
For VMware ESXi 5.x systems, monitoring the status of a RAID array with NEC ESMPRO is not
supported.