Model
R120d-1M
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Standard, non-hot plug
Redundant Power Supply
Optional, hot plug
Power Supply
1-2 x 450 Watt or 800 Watt 80 PLUS® Platinum certified hot plug
PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
259 VA /
257 Watt
268 VA /
266 Watt
268 VA /
266 Watt
269 VA /
267 Watt
(Max. Config,
Operating)
365 VA /
364 Watt
416 VA /
396 Watt
416 VA /
396 Watt
521 VA /
521 Watt
Acoustical Noise
(Sound Pressure
Level)
2
Max. Config, Idling
48.0 dB
48.0 dB
48.0 dB
48.0 dB
Max. Config, Operating
53.7 dB
53.7 dB
52.4 dB
53.7 dB
Dimensions (W x D x H )
439.8 x 722.0 x 43.4 mm / 17.3 x 28.4 x 1.7 in (1U)
Weight (Minimum / Maximum)
15.2 kg / 23.0 kg, 33.51 lbs. / 50.71 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40° C / 50° to 104° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating Systems
Microsoft® Windows Server® 2003 R2, Standard Edition
Microsoft® Windows Server® 2003 R2, Enterprise Edition
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
3
Microsoft® Windows Server® 2012 Datacenter
3
Red Hat Enterprise Linux 5.7 or later (x86)
4
Red Hat Enterprise Linux 5.7 or later (EM64T)
4
Red Hat Enterprise Linux 6.1 or later (x86)
4
Red Hat Enterprise Linux 6.1 or later (x86_64)
4
VMware ESX 4.1 Update 2
VMware ESXi 5.0 Update 1
VMware ESXi 5.1
1
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
2
Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may
vary by the operating environment.
3
For Windows Server 2012 installation, download the driver kit from the following website and install it after OS
installation
http://www.nec.com/en/global/prod/express/download/
4
For Linux support, contact your sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html