4. RAID System Configuration
Express5800/R120g-1E Maintenance Guide
125
Chapter 2 Useful Features
4.2
Menu Tree of the Legacy Mode
: Selection/execution parameter
: Setting parameter.
•
: Information
: Can be set (modified) after creation of Virtual Drive
Menu
Description
Configure
Setting of Configuration
Easy Configuration
Setting of Configuration (fixed value used)
New Configuration
Create new Configuration
View/Add Configuration
Display or add Configuration
Clear Configuration
Clear Configuration
Select Boot Drive
Select bootable Virtual Drive
Initialize
Initialize Virtual Drive
Objects
Various settings
Adapter
Configure RAID Controller
Sel. Adapter
Select an adapter
Rebuild Rate
30 (Percentage of IO for Rebuild)
Chk Const Rate
30 (Percentage of IO for Check Consistency)
FGI Rate
30 (Percentage of IO for Foreground Initialize)
BGI Rate
30 (Percentage of IO for Background Initialize)
Disk WC
Off (Use or not use Write Cache of Adapter, unavailable on LSI Software
RAID.)
Read Ahead
On (On/Off Read Ahead)
Bios State
Enable (Enable or disable LSI Software RAID BIOS)
Continue on Error
Yes (If LSI Software RAID BIOS detects an error, specify whether the POST
halts or not.)
Fast Init
Enable (Enable or disable Fast Initialize)
Auto Rebuild
On (Enable or disable Auto Rebuild)
Auto Resume
Enable (If the system is restarted during Rebuild or Check Consistency,
specify whether the task is continued automatically or not.)
Disk Coercion
1 GB (Forcibly pack HDDs of different size)
Factory Default
Restore the default value
Summary of Contents for Express5800/R120g-1E
Page 223: ...MEMO...