1. POST Error Message
Express5800/R120g-1E Maintenance Guide
193
Chapter 3 Appendix
Error Message
Cause
Solution
C040
SROM data read error
An error was detected while
reading data on FRU.
Contact your sales representative.
C061
1st SMBus device Error
detected.
An error was detected on 1st SM
Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd SM
Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd SM
Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th SM
Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th SM
Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th SM
Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th SM
Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th SM
Bus.
C101
BMC Memory Test
Failed.
An error was detected on BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C102
BMC Firmware Code
Area CRC check Failed.
C103 BMC
core
hardware failure.
C104 BMC
IBF or OBF check failed.
An error was detected while
accessing BMC.
C105
BMC SEL area full.
There is not enough space to store
the system event log.
Run Offline Tools (
Chapter 1, 9. Offline Tools
)
and clear the event logs.
C10B
BMC operational code
corrupted.
Flash Memory for BMC is faulty.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C10D Internal
Use Area of BMC FRU
corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC
SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111 BMC
SDR Repository failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC
RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115 Management
controller
not responding
Management controller does not
respond.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A SEL
corrupt.
BMC error or illegal system event
log data was detected.
Summary of Contents for Express5800/R120g-1E
Page 223: ...MEMO...