1. POST Error Message
Express5800/R120g-1E Maintenance Guide
194
Chapter 3 Appendix
Error Message
Cause
Solution
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
installed.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in BMC
Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced
Boot Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Unplug the power cord, wait for 30 seconds,
and restart the server. If the same error is
detected repeatedly, contact your sales
representative.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.
C120
BMC Runtime FW corrupted.
An error occurred on BMC Runtime
FW.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server. If the
same error is detected again, contact your
sales representative.
C121
BMC Force Update FW corrupted.
An error occurred on BMC Force
Update FW.
C122
BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123
BMC eMMC inaccessible.
Failed to access to BMC eMMC.
C125
BMC eMMC mode error.
BMC eMMC mode error occurred.
C126
BMC eMMC partition corrupted.
An error occurred on BMC eMMC
partition.
C127
BMC eMMC format corrupted.
A format error occurred on BMC
eMMC.
C128
BMC is in Update Mode.
BMC is in update mode.
C300 Out-of-band
setup
configuration failure
An error was detected while
accessing BMC Mezzanine card.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected.
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration was
detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected
when RAID Controller is installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID Controller is
inappropriate.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
C320 Unmatched PSUs.
Unmatched power supply units are
configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption
exceeds the power output capacity
limit.
C322 No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
C323
Internal Use Area of BMC FRU is
incompatible.
An incompatibility was detected in
FRU containing the device
information.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C501 Intel(R) Node Manager is in
Recovery Mode.
Intel(R) Node Manager is is
Recovery Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.
Summary of Contents for Express5800/R120g-1E