1. Installing Internal Optional Devices
Express5800/R120h-2M User’s Guide
93
Chapter 2 Preparations
Notes
Read the following notes when installing or removing a PCI board.
Do not touch the terminals of the PCI board and the leads of electronic components with your bare hand.
Fingerprints and dust left on them cause the server to malfunction due to a connection failure or damage
to the leads.
Available type of PCI card depends on a riser card. Make sure the card type before connecting it to riser
card.
Supported cards and available slots
The following tables list supported cards and slots available for them. For details of the features of each card,
see the manual supplied with the card.
Tips
Different cards mounted on the same bus operate at the lower frequency.
If the operation performance of PCI card differs from that of PCI Slot, the PCI
card operates at lower frequency.
(1)
List of slots mounting board
Part
number
Part name Riser card name
RAID LOM
1st riser card *3
2nd riser card *3
3rd riser card*3
Remarks
Slot number
-
-
SLOT1 SLOT2 SLOT3
SLOT4
SLOT5
SLOT6
SLOT7
SLOT8
CPU connected
CPU1
CPU2
PCI standard
PCIe3.0
PCI slot performance *1
x8
x8
x8 x16 x8 x16 x8 x16 x8 x16 x8 x16 x8 x16 x8 x16
x8
Bandwidth/lane *1
8Gb/s
PCI board type *2
-
-
x8 x16 x8 x16 x8 x16 x8 x16 x8 x16 x8 x16 x8 x16
x8
Slot size
Dedic
ated
to
RAID
Dedic
ated
to
LOM
FH FH FH FH FH FH FH FH FH FH FH FH FH FH
FH
Available size
FL FL HL HL HL HL FL
FL
HL HL HL HL FL
FL
HL
N8103-189
RAID Controller (0MB, RAID 0/1)
[PCI Express 3.0(x8)]
○
-
-
-
-
-
-
-
-
-
N8103-190
RAID Controller (2GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
○
-
-
-
-
-
-
-
-
-
Maximum of up to 1 battery per
device
N8103-191
RAID Controller (4GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
○
-
-
-
-
-
-
-
-
-
Maximum of up to 1 battery per
device
N8103-195
RAID Controller (0MB, RAID 0/1)
[PCI Express 3.0(x8)]
-
-
1 3 5 2 4 6 7 8
N8103-201
RAID Controller (2GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
-
-
1 3 5 2 4 6 7 8
Maximum of up to 1 battery per
device
N8103-196
RAID Controller (2GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
-
-
1 3 5 2 4 6 7 8
For external device. Maximum of up
to 1 battery per device
N8103-197
SAS Controller (2ch)
[PCI Express 3.0(x8)]
-
-
1 3 5 2 4 6 7 8
For
external
device
N8104-171
1000BASE-T LOM Card (4ch)
[PCI Express 2.0(x8)]
-
○
-
-
-
-
-
-
-
-
N8104-172
1000BASE-T LOM Card (4ch)
[PCI Express 3.0(x8)]
-
○
-
-
-
-
-
-
-
-
N8104-173
10GBASE-T LOM Card (2ch)
[PCI Express 3.0(x8)]
-
○
-
-
-
-
-
-
-
-
N8104-175
10GBASE-T LOM Card (2ch)
[PCI Express 2.0(x8)]
-
○
-
-
-
-
-
-
-
-
N8104-176
10GBASE LOM Card (SFP+/2ch)
[PCI Express 3.0(x1)]
-
○
-
-
-
-
-
-
-
-
N8104-177
25GBASE LOM Card (SFP28/2ch)
(SFP28/2ch)
-
○
-
-
-
-
-
-
-
-
N8104-178
1000BASE-T Card (2ch)
[PCI Express 2.0(x1)]
-
-
1 3 5 2 4 6 7 8
N8104-179
1000BASE-T Card (4ch)
[PCI Express 2.0(x4)]
-
-
1 3 5 2 4 6 7 8
Network cables with RJ-45 plug
covers cannot be used.
N8104-180
1000BASE-T Card (2ch)
[PCI Express 2.0(x4)]
-
-
1 3 5 2 4 6 7 8
Network cables with RJ-45 plug
covers cannot be used.