1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
183
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
286
IMPORTANT: The removal of a storage
device has been detected. The device
has been removed from the Boot
Controller Order.
Action is not necessary.
UEFI
287
IMPORTANT: The removal of a network
device has been detected. The device
has been removed from the Standard
Boot Order (IPL)
Action is not necessary.
UEFI
288
IMPORTANT: A new storage device has
been detected and has been added to
the end of the Boot Controller Order.
Action is not necessary.
UEFI
289
A new network or storage device has
been detected. This device will not be
shown in the Legacy BIOS Boot Order
options in RBSU until the system has
booted once.
Action is not necessary.
UEFI
291
IMPORTANT: The Standard Boot Order
(IPL) has been detected as corrupted
and has been restored to default
values.
Action is not necessary.
UEFI
292
Invalid %1 Software RAID
Configuration. %2 SW RAID Mode is
NOT supported when the Boot Mode is
configured for legacy BIOS Mode.
When using the corresponding Software RAID, the
boot mode must be changed to the UEFI mode. If
the problem persists, contact your sales
representative.
UEFI
297
IMPORTANT: iLO Security is disabled by
the associated switch being set to the
ON position. Platform security is
DISABLED.
The maintenance switch SW1 should be set to OFF
unless the setting is specified in the operating
procedure etc.
When operating the maintenance switch, follow the
procedure in
Chapter 1 (7. Resetting and Clearing
the Server)
in this manual.
If the problem persists, contact your sales
representative.
UEFI
311
%1 Configuration Error - The system
has exceeded the installed battery
capacity.
Add more batteries for the capacity increase, or
reduce the number of devices that need battery
backup. If the problem persists, contact your sales
representative.
UEFI
312
%1 %2 Failure - Communication with
the battery failed. Its output may not
be enabled.
Make sure that the battery is correctly installed. If
the problem persists, contact your sales
representative.
UEFI
313
%1 %2 Failure - Battery Shutdown
Event Code: 0x%3.
Restart the server. If the problem persists, contact
your sales representative.
UEFI
315
An uncorrectable memory error was
detected prior to this system boot.
Contact your sales representative.
UEFI
319
An Unexpected Shutdown was detected
prior to this boot.
Action is not necessary.
UEFI
320
Enclosure Power Event detected. Boot
delayed until condition is resolved.
Action is not necessary.