4. Maintenance of Express5800/ft series
Express5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)
40
Chapter 1 Maintenance
10. Choose
Copy online BIOS image to Offline
and click
Apply
.
11. When you click
OK
on confirmation dialog box, the firmware update starts.
Tips
The update result can be checked by
Status Information
of
General
in target
component ("Firmware update complete" is displayed). In addition, the result of the
update is reported by the ft server as an alert.
It takes about 15 minutes until the update of either of CPU module is completed.
When the firmware update is completed, check that the firmware revision is modified as you expect.
12. Confirm that the update is finished, and then start CPU module.
13. When
Status Information
of
General
of the target component is "Duplex", the update is finished.