12. Offline Tools
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
114
Chapter 1 Maintenance
12.2
Features of Offline Tools
Offline Tools has the following features.
Note
Disable RDX by setting RDX to hibernate mode before starting Offline Tools.
Off-line Maintenance Utility
Off-line Maintenance Utility is started when
Maintenance Utility
is chosen. Off-line Maintenance Utility is
used for preventive maintenance and failure analysis for the server. If you are unable to start NEC ESMPRO
due to a failure, Off-line Maintenance Utility can be used to check the cause of the failure.
Note
Off-line Maintenance Utility is intended for maintenance personnel. Consult with
your sales representative if a trouble that requires Off-line Maintenance Utility
occurs.
Off-line Maintenance Utility has the following features.
–
IPMI Information Viewer
Displays System Event Log (SEL), Sensor Data Record (SDR), and Field Replaceable Unit (FRU) in
Intelligent Platform Management Interface(IPMI) and also back up such logs.
Using this feature, system errors and events can be investigated to locate the component to be
replaced. You can also clear the SEL area, and specify the operation when the SEL area becomes
full.
Tips
DIMM information (DIMMx FRU#y) displayed when you select
Display Most
Recent IPMI Data
Field Replaceable Unit (FRU) List
is the one for CPU/IO
module on primary side.
For the CPU/IO module on opposite side, the following message is displayed.
Ignore the message because this is not a failure.
WARNING!
No Information.
The Device is not detected or it is broken.
–
System Information Viewer
Displays and saves information on processor (CPU) or BIOS.
–
System Information Management
Specifies Product data and other System data.
BMC Configuration
–
Uses this utility to specify the alert notification feature by Baseboard Management Controller (BMC)
and use the remote management feature by "PC for Management".
See
Chapter 3 (2. BMC Configuration)
for more information.