2. BMC Configuration
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
225
Chapter 3 Useful Features
Mail Alert
2.4.3
The
Mail Alert
menu appears when you select
Mail Alert
on
BMC Configuration
menu.
Mail Alert menu
The table below shows details of parameters and their default value.
Item Description
Default
Value
Mail Alert
SMTP Alert
Enable or disable Mail Alert.
Disable
Response of SMTP
Server
Specify the timeout period until when the connection to
SMTP server succeed by E-mail transmission.
30
To:1
Select Enable/Disable of To:1.
*1
Enable
To:1 E-Mail Address
Specify the mail address of To:1.
*2
*3
Blank
To:2
Select Enable/Disable of To:2.
*1
Disable
To:2 E-Mail Address
Specify the mail address of To:2.
*2
*3
Blank
To:3
Select Enable/Disable of To:3.
*1
Disable
To:3 E-Mail Address
Specify the mail address of To:3.
*2
*3
Blank
From:
Specify the mail address of From.
*3
Blank
Reply-To:
Specify the mail address of Reply-To.
*3
Blank
Subject:
Specify the Subject.
*4
Blank
Subject
Option
Enable or disable the feature to add Subject Option.
Disable
X-Priority/Date
Format
Enable or disable the feature to add X-Priority, and select date
format.
Enable /
MM/DD/YYYY
SMTP Server
SMTP Server
Specify the SMTP Server.
*5
0.0.0.0
SMTP Port Number
Specify the SMTP port number.
25
SMTP Authentication
Select Enable/Disable of SMTP Authentication. Disable
CRAM-MD5
Select Enable/Disable of CRAM-MD5.
*6
*7
Enable
LOGIN
Select
Enable/Disable of LOGIN authentication.
*6
*7
Enable
PLAIN
Select Enable/Disable of PLAIN authentication.
*6
*7
Enable
User Name
Specify the SMTP User Name.
*6
*8
Blank
Password
Specify the SMTP User Password.
*6
*9
Blank
Alert Level
Alert Level
Specify the kind of event to alert.
*10
Error,
Warning
Error
: When "Error" is detected in each sensor type, the
alert is sent to the checked address.
Error,
Warning
: When "Error" or "Warning" is detected in each sensor
type, the alert is sent to the checked address.
Error, Warning, Information
: When "Error", "Warning" or "Information" is detected
in each sensor type, the alert is sent to the checked