6. Error Messages
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
63
Chapter 1 Maintenance
Error Message
Description
Action
C061
1st SMBus device Error
detected.
An error was detected on 1st SM Bus. Contact your sales representative.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd SM Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd SM Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th SM Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th SM Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th SM Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th SM Bus.
C101
BMC Memory Test
Failed..
An error was detected on BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C102
BMC Firmware Code
Area CRC check
Failed.
C103
BMC core hardware
failure.
C104
BMC IBF or OBF check
failed.
An error was detected while accessing
BMC.
C105
BMC SEL area full.
There is not enough space to store the
system event log.
Start up Offline Tools (
Chapter 1, 12. Offline
Tools
) and delete the event logs.
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C10D
Internal Use Area of BMC
FRU corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111
BMC SDR Repository
failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in BMC.
C115 Management
controller
not responding
Management controller does not
respond.
Update the BMC firmware.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A SEL
corrupt.
BMC error or illegal system event log
data was detected.