1. POST Error Message
Express5800/T120e Maintenance Guide
123
Chapter 3 Appendix
(5/7)
Error Message
Cause
Solution
B234
PCI Slot 4 - PCIE Link Width
Error
A Link Width error was detected
in PCI Slot 4.
B235
PCI Slot 5 - PCIE Link Width
Error
A Link Width error was detected
in PCI Slot 5.
B261 Onboard
LAN 1 – PCIe Link Speed
Error
Link Speed error was detected
on onboard LAN1.
B262 Onboard
LAN 2 – PCIe Link Speed
Error
Link Speed error was detected
on onboard LAN2.
B271
PCI Slot 1 - PCIE Link Speed
Error
A Link Speed error was
detected in PCI Slot 1.
B272
PCI Slot 2 - PCIE Link Speed
Error
A Link Speed error was
detected in PCI Slot 2.
B273
PCI Slot 3 - PCIE Link Speed
Error
A Link Speed error was
detected in PCI Slot 3.
B274
PCI Slot 4 - PCIE Link Speed
Error
A Link Speed error was
detected in PCI Slot 4.
B275
PCI Slot 5 - PCIE Link Speed
Error
A Link Speed error was
detected in PCI Slot 5.
Contact your sales representative.
C000
The error occurred during fan
sensor reading.
An error was detected while
reading fan sensor.
C010
The error occurred during
temperature sensor reading
An error was detected while
reading temperature sensor.
Contact your sales representative.
C011
System Temperature out of the
range.
A temperature abnormality was
detected.
It is possible that an ambient temperature of
installation site is high, or a fan has failed or is
clogged. Contact your sales representative.
C020
The error occurred during
voltage sensor reading.
An error was detected while
reading voltage sensor.
C021
System Voltage out of the
range.
A system voltage abnormality
was detected.
C040
SROM data read error
An error was detected while
reading data on SROM.
C041
SROM data checksum bad
A checksum error was detected
while reading FRU data.
C061
1st SMBus device Error
detected.
An error was detected on 1st
SM Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd
SM Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd
SM Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th
SM Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th
SM Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th
SM Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th
SM Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th
SM Bus.
Contact your sales representative.
C101
BMC Memory Test
Failed..
An error was detected on BMC.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
An error was detected while
accessing BMC.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
C105
BMC SEL area full.
There is not enough space to
store the system event log.
Start up Offline Tools (Chapter 1, 9. Offline Tools)
and delete the event logs.
C10B
BMC operational code
corrupted.
Failed to start BMC firmware.
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.