1. POST Error Message
Express5800/T120e Maintenance Guide
124
Chapter 3 Appendix
(6/7)
Error Message
Cause
Solution
C10D
Internal Use Area of BMC
FRU corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111
BMC SDR Repository
failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C115
Management controller
not responding
Management controller does not
respond.
Update the BMC firmware.
If the same error is detected repeatedly, contact
your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A
SEL corrupt.
BMC error or illegal system event log
data was detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not installed.
C11C
BMC Mezzanine partition
is invalid.
A format error was detected in BMC
Mezzanine card.
Contact your sales representative.
C11D
BMC is in Forced Boot
Mode.
Detected that BMC is in Forced Boot
Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
C11F
Backup Data of BMC
Mezzanine card has
corrupted.
Backup Data of BMC Mezzanine card
has corrupted.
C200
The error occurred during
memory configuration
check.
Memory configuration could not be
obtained.
Contact your sales representative.
C201
Memory Configuration
change is detected.
The memory configuration has
changed since the previous startup.
When Check previous system Config is enabled in
Server of the setup, this message appears if the
configuration was changed since the previous
startup. If this message appears even when no
configuration change has been made, contact your
sales representative.
C202
The error occurred during
CPU configuration check.
The CPU configuration data could not
be acquired.
Contact your sales representative.
C203
CPU Configuration change
is detected.
The CPU configuration has changed
since the previous startup.
When Check previous system Config is enabled in
Server of the setup, this message appears if the
configuration was changed since the previous
startup. If this message appears even when no
configuration change has been made, contact your
sales representative.