- 51 -
Error
Correct
P.83
(3) Memory ADDDC
function
From the System Utilities, select "System
Configuration > BIOS/Platform Configuration
(RBSU) >
System Options > Memory
Operations
" to set "Advanced Memory
Protection" to "Fault Tolerant Memory
(ADDDC)".
From the System Utilities, select "System
Configuration > BIOS/Platform Configuration
(RBSU) >
Memory Options
" to set
"Advanced Memory Protection" to "Fault
Tolerant Memory (ADDDC)".
P.83
(3) Memory ADDDC
function - Note
The DIMM compatible with the memory
ADDDC function is
"N8102-709", "N8102-
711", and "N8102-712"
.
The DIMM compatible with the memory
ADDDC function is
"N8102-
709/711/712/713"
.
P.118
1.16.2 Supported PCI
cards and available
slots
*3 A maximum of 1 battery can be
implemented per
device
*3 A maximum of 1 battery can be
implemented per
system
P.134
1.21.2 Installing
N8103-198 Extension
Battery in a Normal
Setting
1.21.2 Installing
N8103-198
Extension
Battery in a Normal Setting
1.21.2 Installing
N8103-203
Extension
Battery in a Normal Setting
P.137
1.22.1 Installing the
Internal Drive DVD-
ROM N8151-
137/DVD-Super
MULTI N8151-138
●T-
10
hexalobular driver
●
Optical disk drive cable kit
(K410-375(00))
●T-
15
hexalobular driver
●
Internal DVD Drive Installation Kit
(N8154-122)
P.139
1.22.1 Installing the
Internal Drive DVD-
ROM N8151-
137/DVD-Super
MULTI N8151-138
7. Connect the optical disk drive connector to
the onboard SATA port 5 connector on the
motherboard with the SATA cable for
optical
disk drive (K410-375 (00))
.
Wire the cables as shown below.
7. Connect the optical disk drive connector to
the onboard SATA port 5 connector on the
motherboard with the SATA cable for
Internal DVD Drive Installation Kit (N8154-
122)
.
For the wireing of cables, refer to the
diagram below.
P.141
1.23.1 Notes on
Building RAID System
If the optional RAID Controller (N8103-189/
195) is used, the RAID System cannot be built
in
RAID5/RAID6/RAID50/RAID60
.
RAID level
The minimum number of hard
disk drives required to set up
a RAID System
N8103-
189/195
N8103-
190/191/196/201
RAID 0
1
1
RAID 1
2
2
RAID 5
3
RAID 6
3
RAID 10
4
4
RAID 50
6
RAID 60
6
If the optional RAID Controller (N8103-189/
195) is used, the RAID System cannot be built
in
RAID6/RAID50/RAID60
.
RAID level
The minimum number of hard
disk drives required to set up
a RAID System
N8103-
189/195
N8103-
190/191/196/201
RAID 0
1
1
RAID 1
2
2
RAID 5
3
3
RAID 6
4
RAID 10
4
4
RAID 50
6
RAID 60
8
P.204
1. Specifications -
Memory - Standard /
Maximum
Not included / Registered DIMM: 768GB (24x
32GB), Load Reduced DIMM:
1.5TB (24x
64GB)
Not included / Registered DIMM: 768GB (24x
32GB), Load Reduced DIMM:
3.0TB (24x
128GB)
P.204
1. Specifications -
Memory - Memory
module
DDR4-2666 Registered DIMM (8/16/32GB),
DDR4-2666 Load Reduced DIMM
(64GB)
DDR4-2666 Registered DIMM (8/16/32GB),
DDR4-2666 Load Reduced DIMM
(64/128GB)