8000 - Voice Mail
8005 - IntraMail Master Mailbox Options
IntraMail System Guide
Chapter 3: Programming
◆
225
3
8005 Program Entry
8005 - Master Mailbox Options Program Entry
(Prior to 03.20.07)
(Entry Range) [Default Setting]
ICM
+
#*#*
+ Password (372000) +
HOLD
+
8005
+
HOLD
.
EXTENSION
(Master Mailbox number 600-607 or 700-707)
MAILBOX TYPE
(1 = Call Routing, 2 = Announcement, 3 = Subscriber, 0 = Unde
fi
ned) [Subscriber]
For Call Routing Mailboxes (Type 1)
DIAL ACTION TABLE
(1-16) [1]
SCRN TRF TIMEOUT
(0-255 seconds) [15]
DIALING TIMEOUT
(0-99 seconds) [5]
INCOMING FAX DET
(Yes/No) [No]
To program the
MAILBOX ACTIVE
option, press
Vol Up
(not
HOLD
) after
selecting a Mailbox type.
MAILBOX ACTIVE
(Yes/No) [No]
For Announcement Mailboxes (Type 2)
NEXT CALLRT MBOX
(000-015, CLEAR = UND) [UND]
NUM REPEATS
(0-10) [0]
HANG-UP
(Yes/No) [No]
To program the
MAILBOX ACTIVE
option, press
Vol Up
(not
HOLD
) after
selecting a Mailbox type.
MAILBOX ACTIVE
(Yes/No) [No]
For Subscriber Mailboxes (Type 3)
NUMBER OF MSGS
(0-99) [20]
MESSAGE PLAYBK
(3=FIFO, 5=LIFO) [FIFO]
MESSAGE OPTION
(3=Erase. 7=Save)[Save]
MSG RETENTION
(1-90 Days, CLEAR = IND) [IND]
REC CONV BEEP
(Yes/No) [Yes]
UPDATE MW LAMP
(Yes/No) [Yes]
AUTO-ATT DND
(Yes/No) [No]
FORCE UTRF
(Yes/No) [No]
AUTO TIME STAMP
(Yes/No) [No]
SYSTEM ADMIN
(Yes/No) [No]
DIALING OPTION
(Yes/No) [No]
NEXT CALLRT MBOX
(000-015, CLEAR = UND) [UND]
To program the
MAILBOX ACTIVE
option, press
Vol Up
(not
HOLD
) after
selecting a Mailbox type.
MAILBOX ACTIVE
(Yes/No) [No]