25
7.2.
“
CURRENTSOURCE
”
Control procedure
7.2.1. Current Source Control
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x01)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x01) :
‘
Current Source
’
parameter
Value : Data value
0 : AV1
1 : AV2
2 : AV3
6 : COMPONENT
9 : DVI
10 : DSUB
7.2.2. Current Source state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x01)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x01) :
‘
Current Source
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Source getting value
0 : AV1
1 : AV2
2 : AV3
6 : COMPONENT
9 : DVI
10 : DSUB