47
7.24.
“
Equalizer
”
Control procedure
7.24.1. Equalizer Control
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter
0x1D : EQ 100Hz
0x1E : EQ 300Hz
0x1F : EQ 1KHz
0x20 : EQ 3KHz
0x21 : EQ 10KHz
Value: 0 ~ 20 (range)
7.24.2. Current BALANCE state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter
0x1D : EQ 100Hz
0x1E : EQ 300Hz
0x1F : EQ 1KHz
0x20 : EQ 3KHz
0x21 : EQ 10KHz
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Equalizer getting value
0 ~ 20 (range)