50
7.27.
“
ONTIMEONOFF
”
Control procedure
7.27.1. ONTIMEONOFF Control ( Power ON time control )
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x24)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x24) :
‘
ONTIMEONOFF
’
parameter
Value: Data value
0 : Disable
1 : Enable
7.27.2. Current ONTIMEONOFF state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x24)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x24) :
‘
ONTIMEONOFF
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current ONTIMEONOFF getting value
0 : Disable
1 : Enable