037. INFORMATION REQUEST
**********************************************************************
Function:
This command acquires the projector information.
Command:
03H 8AH 00H 00H 00H 8DH
Response: At the time of a success
23H 8AH 01H xxH 62H DATA01 .. DATA98 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 .. 49 : Projector name (NULL termination character string)
DATA50 .. 82 : Reserved
DATA83 .. 86 : Lamp Hour Meter (second) (!)
DATA87 .. 90 : Filter Usage (second)
DATA91 .. 94 : Panel Usage (second)
DATA95 .. 98 : Projector Usage (second)
Response: At the time of a failure
A3H 8AH 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
Supplement:
(!) Lamp Hour Meter
This is the timer for normal lamp mode conversion.
Lamp Timer Acquisition Examples
DATA83 DATA84 DATA85 DATA86 : Lamp Timer
00H 00H 00H 00H : Total 0 seconds
C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours
00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600 hours
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0)
3) Change from HEX to Decimal - value will change to 5400000 seconds
* The projector's hours of use is displayed in terms of Normal mode values.
It is also displayed with truncated a number after decimal point.
037-1. LAMP INFORMATION REQUEST
**********************************************************************
Function:
This command acquires the lamp information (in terms of Normal mode (values) of projector.
Command:
03H 8CH 00H 00H 00H 8FH
Response: At the time of a success
23H 8CH 01H xxH 10H DATA01 .. DATA16 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 .. 04 : Lamp Hour Meter(Normal mode) (second)