- 7-
Table 3.2 NEC Storage M300 Product Specifications
Numbers in the table are calculated based on 1 GB = 1,000,000,000 bytes and 1TB = 1,000,000,000,000 bytes.
Product Name
NEC Storage M300 Disk Array Unit
Configuration
2.5”(24HDD model)
3.5”(12HDD model)
min
max
min
max
Storage
capacity
*1 *2
SAS HDD
configuration
300GB disk drive
282GB
36.4TB
282GB
24.3TB
450GB disk drive
435GB
56.0TB
435GB
37.3TB
600GB disk drive
571GB
73.4TB
571GB
48.9TB
600GB encrypted disk drive
571GB
73.4TB
571GB
48.9TB
900GB disk drive
874GB
112.1TB
-
-
1.2TB disk drive
1.16TB
149.4TB
-
-
NL-SAS HDD
configuration
1TB disk drive
979GB
125.7TB
979GB
83.7TB
2TB disk drive
-
-
1.9TB
166.8TB
3TB disk drive
-
-
2.9TB
249.0TB
4TB disk drive
-
-
3.9TB
333.4TB
SAS SSD
configuration
100GB drive
89GB
897GB
89GB
897GB
200GB drive
187GB
1.4TB
187GB
1.4TB
400GB drive
387GB
3.7TB
387GB
3.7TB
800GB drive
757GB
5.9TB
757GB
5.9TB
Chassis
dimensions
(W×D×H)
Disk array
controller
(U count)
without Front Bezel
482×513.2×87.8mm(2U)
with Front Bezel
482×545.2×87.8mm(2U)
Disk enclosure
(U count)
without Front Bezel
482×513.2×87.8mm(2U)
with Front Bezel
482×545.2×87.8mm(2U)
Weight
Disk array controller
< 31kg
Disk enclosure
< 29kg
Accessories (Rails for rack mount, cables)
< 3kg
Power
Supply
100V to 240V AC, single phase 50/60Hz *3
Power
consumption
SAS HDD configuration
(3.5”15Krpm)
-
-
510W
2715W
SAS HDD configuration
(2.5”15Krpm)
505W
2055W
-
-
SAS HDD configuration
(2.5”10Krpm)
505W
2055W
-
-
NL-SAS HDD configuration
(2.5”/3.5”7.2Krpm)
470W
1845W
455W
2310W
Inrush
current
(peak)
Main chassis
25Ao-p/AC line
Disk enclosure
25Ao-p/AC line
Temperature / Humidity conditions
During operation : +5C to +40C / 10% to 80%
During storage : -10C to +60C / 5% to 80%
Redundancy
Main components such as controller, cache, power supply,
and fan are duplicated