Release 6.0
282
User Guide
Chapter 10 Troubleshooting
10.3.2 Errors in Initialization
Problem
Cause and Solution
Configuring any the following failed.
Setting disk array subsystem
name.
Setting the time (synchronization
with the NTP server)
Setting the time (manually)
Unlocking a license
Setting host connection port
(iSCSI)
Setting iSNS server
Setting host connection port (FC)
Port mode switching
Setting host connection port (SAS)
It is conceivable that a disk array problem or communication
error between the disk array and a client has occurred.
Check if the disk array or the client has a problem. Fix the
problem and then perform initialization again.
An error occurred in the completion
page of the initialization.
This problem may occur when the next generation Java
plug-in is not disabled.
See
Section 4.5.1: “Before Starting NEC Storage Manager
to disable the next generation Java plug-in, and then
perform the initialization again.
Whenever Storage Manager is
started, the dialog prompting to start
initialization is displayed.
This problem occurs when initialization is not completed
successfully.
Start the initialization wizard and complete it successfully.
Summary of Contents for M100
Page 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Page 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Page 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Page 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Page 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Page 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Page 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...