Release 6.0
391
User Guide
Appendix F How to Set/Check Application Server (Linux) (iSCSI)
Setup method when using
CHAP authentication of Initiator
.
1. Use
vi
or another editor to open the
/etc/iscsi/iscsid.conf
file on the server.
2. After editing the file as shown below, save and close the file.
3. Restart the iSCSI service
Setup method when using
bidirectional CHAP authentication
.
1. Use
vi
or another editor to open the
/etc/iscsi/iscsid.conf
file on the server.
2. Edit the file as shown below, then save and close the file.
node.session.auth.authmethod = CHAP
node.session.auth.username = <iqn (username) of server>
node.session.auth.password = <password of CHAP Initiator>
(Example)
node.session.auth.authmethod = CHAP
node.session.auth.username = iqn.1991-05.com.microsoft.exp120rj
node.session.auth.password = jR021_0085sserpxE
# /etc/init.d/iscsi stop
# /etc/init.d/iscsi start
The CHAP Initiator password that is set here is a password that a target uses
to authenticate the Initiator. This password is also required for settings on the
disk array side (see
Section: 15.3.21 iSMcfg setldsetchap in the NEC
Storage Manager Command Reference
), so be sure to write it down so it is
not forgotten.
node.session.auth.authmethod = CHAP
node.session.auth.username = <iqn (username) of server>
node.session.auth.password = <password of CHAP Initiator>
node.session.auth.username_in= <iqn (username) of disk array>
node.session.auth.password_in = < password of CHAP target>
(Example)
node.session.auth.authmethod = CHAP
node.session.auth.username = iqn.1991-05.com.microsoft.exp120rj
node.session.auth.password = jR021_0085sserpxE
node.session.auth.username_in =
iqn.2001-03.jp.nec:storage01:ist-m000-sn-
0000000938209213.wn-0.target0000 -p 192.168.10.64:3260
node.session.auth.password_in = i3DegarotsiCEN
Summary of Contents for M100
Page 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Page 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Page 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Page 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Page 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Page 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Page 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...