79
3.48
[ 305-1. BASE MODEL TYPE REQUEST ]
Gets the base model type of the projector.
Command
00h BFh 00h 00h 01h 00h C0h
Response
When the command succeeds
20h BFh
<ID1>
<ID2>
10h 00h
<DATA01>
-
<DATA15>
<CKS>
Data part
Item
Description
DATA01
DATA02
Base model type
DATA03 - 11
Model name (NUL: termination character string)
DATA12
DATA13
Base model type
DATA14
DATA15
Reserved for the system
Information
For the values of the base model types, see the Appendix "Supplementary Information by Command".
When the command fails
A0h BFh
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>