English−70
SNMP Settings
Click on “SNMP” on the left-hand column below HOME.
The SNMP protocol is used to get status information and to control a monitor directly via the network.
VersionN
SNMP v1 Authenticated plain text by community name, does not return a confirmation message of the trap.
SNMP v2c Authenticated plain text by community name, returns a confirmation message of the trap.
Community nameN
The default setting of community name is “public”. It is read-only. You can set community names for up to 3 settings.
TrapN
Sending error message to a specified address when an error occurs in the monitor.
Check Box
Explanation
Error code
Temperature
Temperature abnormal
0xA0, 0xA1, 0xA2
Fan
Cooling fan abnormal
0x80, 0x81
Power
Power abnormal
0x70, 0x71, 0x72, 0x78
Inverter/Backlight
Inverter or backlight abnormal 0x90, 0x91
No Signal
No signal
0xB0
PROOF OF PLAY
Lower the log storage
0xD0
System Error
System error
0xE0
AMX Settings
Click on “AMX” on the left-hand column below HOME.
AMX BEACON
To turn on or off for the detection from AMX Device Discovery when connecting to a network
supported by an AMX’s NetLinx control system.
HINT:
When using a device that supports AMX Device Discovery, all AMX NetLinx control systems will
recognize the device and download the appropriate Device Discovery Module from an AMX server.
Selecting [ENABLE] AMX Device Discovery will detect the device.
Selecting [DISABLE] AMX Device Discovery will not detect the device.