Troubleshooting 8-23
Error
code
Error message
Recommended Action
0B94
IPMB signal lines do not respond.
All the functions other than the function of
accessing to SMC through IPMB can be used.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B95
BMC FRU device failure.
All the commands and functions other than the
FRU command and the EMP function can be
used. This is not a fatal error. Turn off the
power once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
0B9A
BMC not responding.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0BB0
SMBIOS - SROM data read error.
0BB1
SMBIOS - SROM data checksum bad.
Contact your service representative.
0BC0
POST detected startup failure of 1st
Processor.
0BC1
POST detected startup failure of 2nd
Processor.
0BC2
POST detected startup failure of 3rd
Processor.
0BC3
POST detected startup failure of 4th
Processor.
Contact your service representative to replace
the processor.
8120
Unsupported DIMM detected in DIMM
group #1.
8121
Unsupported DIMM detected in DIMM
group #2.
8122
Unsupported DIMM detected in DIMM
group #3.
8123
Unsupported DIMM detected in DIMM
group #4.
8124
Unsupported DIMM detected in DIMM
group #5.
8125
Unsupported DIMM detected in DIMM
group #6.
8126
Unsupported DIMM detected in DIMM
group #7.
8127
Unsupported DIMM detected in DIMM
group #8.
Contact your service representative to replace
the two DIMMs in the relevant group.
Summary of Contents for N8100-1220F
Page 7: ......
Page 8: ......
Page 9: ......
Page 38: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 76: ...2 38 General Description This page is intentionally left blank...
Page 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Page 494: ...F 4 Product Configuration Record Table This page is intentionally left blank...