8-44 Troubleshooting
Fail to access the (internal or external) SCSI devices:
T
Is the SCSI device applicable to the server?
→
Operation of any SCSI device that is not authorized by NEC is not guaranteed.
T
Are SCSI devices properly configured?
→
When the server has external SCSI devices connected, device settings, including
SCSI ID and terminator, are required. Refer to the manual that comes with the
SCSI device for details.
T
Are the SCSI controllers (including optional controllers) properly configured?
→
Use the BIOS setup utility for proper configuration of SCSI devices connected to
the SCSI connector on the I/O board. When the server has an optional SCSI
controller installed and SCSI devices connected to it, use the BIOS setup utility
that comes with the optional SCSI controller for proper configuration. See the
manual that comes with the optional SCSI controller for details.
There are some cases that an event log shown below is registered in MegaRAID Storage
Manager (MSM) every time you power on the server.
Controller ID:a Unexpected sense PD=b:255 , CDB=0x1c, …, Sense=0x70,
0x00, 0x06, 0x00, 0x00, 0x00, 0x00, 0x0a, 0x00, 0x00,0x00, 0x00, 0x29,…
a: Controller number of LSI Logic MegaRAID
SAS PCI EXPRESS
ROMB
Normally, the controller ID is "0". It depends on the number of disk array controller
cards N8103-90 installed in PCI-Express slot.
b: SAS port number of LSI Logic MegaRAID
SAS PCI EXPRESS
ROMB
(1: Port 0-3, 2: Port 4-7)
→
It is not a problem in operating the system.
There are some cases that an event log shown below is registered in application log of Event
Viewer every time you power on the server.
Event Source: MR_MONITOR
Event Type:
Warning
Event ID:
113
Description: Controller ID:a Unexpected sense PD=b:255 , CDB=0x1c, …,
Sense=0x70, 0x00, 0x06, 0x00, 0x00, 0x00, 0x00, 0x0a, 0x00, 0x00,0x00,
0x00, 0x29,…
a: Controller number of LSI Logic MegaRAID
SAS PCI EXPRESS
ROMB
Normally, the controller ID is "0". It depends on the number of disk array controller
cards N8103-90 installed in PCI-Express slot.
b: SAS port number of LSI Logic MegaRAID
SAS PCI EXPRESS
ROMB
(1: Port 0-3, 2: Port 4-7)
→
It is not a problem in operating the system.
Summary of Contents for N8100-1220F
Page 7: ......
Page 8: ......
Page 9: ......
Page 38: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 76: ...2 38 General Description This page is intentionally left blank...
Page 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...