8-52 Troubleshooting
PCI hot-plug fails:
T
Is BIOS configuration correct?
→
You must change the BIOS configuration to use the PCI hot-plug feature.
<Menus to check: [Advanced] - [PCI Configuration] - [Hot Plug PCI Control] -
[Minimum/Middle/Maximum*]>
* Setting value depends on the board to be installed. See Chapter 4 for details.
The driver of a PCI board cannot be stopped from the OS when Hot Remove or Hot Replace is
executed for the PCI board:
T
Is another software using the PCI board for which Hot Remove or Hot Replace is to
be executed?
→
If another software is using the PCI board for which Hot Remove or Hot Replace
is to be executed, the driver of the PCI board cannot be stopped.
Terminate the software, then stop the driver of the PCI board. If executing Hot
Replace, restart the software after having mounted a new PCI board.
The Telnet Service is not installed.
→
Adjust the computer name to 14 characters or less, and then install the Telnet Service
according to <How to install the Telnet Service>.
<How to install the Telnet Service>
1.
Click [Run] on Start menu.
2.
Type "tlntsvr /service" in the [Open] box, and click [OK].
3.
Click Start menu, point to [Control Panel] and click [Computer Management] and then
click the [Services] to specify whether the Telnet Service is registered.
* When the installation of Telnet Service is finished, there is no problem if the computer
name is set to 15 characters or more.
Summary of Contents for N8100-1220F
Page 7: ......
Page 8: ......
Page 9: ......
Page 38: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 76: ...2 38 General Description This page is intentionally left blank...
Page 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...