Troubleshooting 8-49
The OS presents unstable operation:
T
Did you update the system?
→
Installing a network drive after installation of the OS may cause unstable
operation. Use the NEC EXPRESSBUILDER CD-ROM to update the system.
(See Chapter 6.)
When any trouble occurred, the system does not run according to the specification of "Restart
automatically":
→
When any trouble occurred on Windows 2003, the system may not restart
automatically even if "Restart automatically" is specified. In such case, restart
the system manually.
Cannot turn the power OFF at the blue screen:
→
If you want to turn off the power at the blue screen, execute forced power off
(forced shut down: continue to press POWER switch for 4 seconds). The power
will not be turned off if you press the switch just one time.
The server is not found on the network:
T
Is the LAN cable connected?
→
Make sure to connect the LAN cable to the network port on the rear of the server.
Also make sure that the LAN cable to use conforms with the network interface
standard.
T
Is BIOS configuration correct?
→
The internal LAN controller may be disabled with the BIOS setup utility of the
server. Check the setting with the BIOS setup utility.
<Menus to check:
[Advanced] - [PCI Configuration] - [Embedded NIC 1], [Embedded NIC 2]>
T
Have the protocol and service already configured?
→
Install the distinctive network driver for the server. Make sure that the protocol,
such as TCP/IP, and services are properly specified.
T
Is the transfer speed correct?
→
Open the network property dialog box in control panel to specify the "Link Speed
& Duplex" value the same as the value specified for HUB.
Summary of Contents for N8100-1223F
Page 6: ......
Page 7: ......
Page 8: ......
Page 10: ...This page is intentionally left blank...
Page 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Page 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Page 294: ...7 12 Maintenance This page is intentionally left blank...