8-6 Troubleshooting
Hard Disk Drive Lamp
The disk lamp on the hard disk drive bay has different meanings depending on the display status.
Lighting green
Indicates that the power is supplied to the hard disk drive.
Blinking green
Indicates that the hard disk drive is accessed.
Lighting amber
Indicates that the installed hard disk drive is defected in the RAID System.
NOTE:
While hard disk drives are in the RAID System configuration
(RAID1, RAID5, RAID6, or RAID10), a single failed hard disk drive
(two hard disk drives in RAID6) does not affect the operation of the
server. However, it is recommended to replace the failed hard disk drive
and rebuild (reconfigure) the hard disk drives as soon as possible. (You
can hot-swap such a failed hard disk drive.)
Alternate lighting green or amber
Indicates that the hard disk drive is being rebuilt (this status is not a failure). If the
defected hard disk drive is replaced with a new one in RAID system, the data is
automatically rebuilt (auto rebuild function). During the rebuild process, the lamp is lit
green or amber alternately.
The lamp goes off when the rebuild is completed normally. The lamp goes on amber if the
rebuild fails.
IMPORTANT:
To abort rebuilding, power off the server. In such a
case, restart the server, hot-swap the failed hard disk drive, and restart
rebuilding. Observe the following notes to use the auto-rebuild feature.
Do not power off the server. (If the server is powered off before
rebuilding hard disk drives, the auto-rebuild feature will not start.)
When you removed a hard disk drive, wait at least 90 seconds
before installing the hard disk drive back again.
Do not replace another hard disk drive while rebuilding is in
progress.
Lamp
Lamp
2.5-inch hard disk drive
3.5-inch hard disk drive
Summary of Contents for N8100-1417F
Page 16: ...x This page is intentionally left blank...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Page 220: ...7 12 Maintenance This page is intentionally left blank...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Page 362: ...A 2 Specifications This page is intentionally left blank...
Page 370: ...C 2 IRQ This page is intentionally left blank...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...