8-10 Troubleshooting
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The following
table lists error codes, error messages, and actions to take.
IMPORTANT:
Take a note on the messages displayed before
consulting with your service representative. Alarm messages are useful
information for maintenance.
Error
code
Error message
Recommended Action
0200
Failure Fixed Disk.
Contact your service representative.
0210
Stuck Key.
Disconnect the keyboard and connect it again.
0211
Keyboard error
Disconnect the keyboard and connect it again.
If the error cannot be corrected, contact your
service representative.
0213
Keyboard locked - Unlock key switch.
Release the lock of the key switch. If the error
cannot be corrected in spite of the release of
the lock, contact your service representative.
0220
Monitor type does not match CMOS - Run
SETUP.
Start the SETUP. If the error cannot be
corrected in spite of the start of SETUP,
contact your service representative.
0230
System RAM Failed at offset.
0231
Shadow Ram Failed at offset.
0232
Extended RAM Failed at address line.
Contact your service representative.
0250
System battery is dead - Replace and run
SETUP.
Contact your service representative to replace
the battery. (After restarting the computer, start
the SETUP to provide the setting again.)
0251
System CMOS checksum bad - Default
configuration used.
The default values have just been set. Start
the SETUP to provide the setting again. If the
error cannot be corrected, contact your
service representative.
0252
Password checksum bad - Passwords
cleared.
The password has just been cleared. Start the
SETUP to provide the setting again.
0260
System timer error.
0270
Real time clock error.
0271
Check date and time setting.
Start the SETUP to set the date and time
again. If the same error occurs successively in
spite of the resetting, contact your service
representative.
0280
Previous boot incomplete - Default
configuration used.
Start the SETUP to provide the setting again.
0281
Memory size found by POST differed from
EISA CMOS.
Initialize EISA CMOS.
02D0
System cache error - Cache disabled.
The cache cannot be used. Contact your
service representative.
Summary of Contents for N8100-1417F
Page 16: ...x This page is intentionally left blank...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Page 220: ...7 12 Maintenance This page is intentionally left blank...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Page 362: ...A 2 Specifications This page is intentionally left blank...
Page 370: ...C 2 IRQ This page is intentionally left blank...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...