9-90 Upgrading Your Server
The table below lists examples of DIMM installation patterns enabling the memory mirroring
feature to be used.
Memory Set
(Group #)
Memory Set
(Group #)
Memory Set
(Group #)
Capacity
Example
#1
#2
#3
#4
#5
#6
Physical
Logical
1
2GB
2GB
-
-
-
-
4GB
2GB
2
2GB
2GB
1GB
1GB
-
-
6GB
3GB
3
2GB
2GB
2GB
2GB
-
-
8GB
4GB
4
2GB
2GB
1GB
1GB
1GB
1GB
8GB
4GB
5
2GB
2GB
1GB
1GB
2GB
2GB
10GB
5GB
6
2GB
2GB
2GB
2GB
1GB
1GB
10GB
5GB
7
2GB
2GB
4GB
4GB
4GB
4GB
12GB
6GB
8
2GB
2GB
2GB
2GB
2GB
2GB
12GB
6GB
9
2GB
2GB
1GB
1GB
4GB
4GB
14GB
7GB
10
2GB
2GB
4GB
4GB
1GB
1GB
14GB
7GB
11
2GB
2GB
2GB
2GB
4GB
4GB
16GB
8GB
12
2GB
2GB
4GB
4GB
2GB
2GB
16GB
8GB
13
2GB
2GB
4GB
4GB
4GB
4GB
20GB
10GB
14
4GB
4GB
4GB
4GB
4GB
4GB
24GB
12GB
15
8GB
8GB
8GB
8GB
8GB
8GB
48GB
24GB
Notes on Configuring Memory Mirroring
In memory mirroring configuration, the menus related to memory mirroring in BIOS SETUP are
grayed out and unselectable in the following cases:
When you additionally install DIMMs that unable to configure memory mirroring
When you remove DIMMs that takes down the memory mirroring
In this case, execute [Load Setup Defaults] to cancel the memory mirroring configuration.
<Procedure>
1.
Take a note of settings in BIOS SETUP.
2.
Press
F2
during POST to run BIOS SETUP utility.
3.
Select [Exit]
→
[Load Setup Defaults].
4.
When a message "Load default configuration now?" appears, select [Yes].
5.
Enter the parameter values you have saved in step (1).
NOTE:
Executing [Load Setup Defaults] restores the default values
for all Setup parameters. You need to specify those parameters again.
Summary of Contents for N8100-1417F
Page 16: ...x This page is intentionally left blank...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Page 220: ...7 12 Maintenance This page is intentionally left blank...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Page 362: ...A 2 Specifications This page is intentionally left blank...
Page 370: ...C 2 IRQ This page is intentionally left blank...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...