8-8 Troubleshooting
Error
code
Error message
Recommended Action
0280
Previous boot incomplete - Default
configuration used.
Run SETUP to provide the setting again.
0281
Memory size found by POST differed from
EISA CMOS.
Initialize EISA CMOS.
02D0
System cache error - Cache disabled.
The cache is unavailable. Contact your
service representative.
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not writeable.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0611
IDE configuration changed
0612
IDE configuration error - device disabled
Check IDE configuration.
0615
Com B configuration changed
0616
Com B config. error - device disabled
Check COM B configuration.
0B22
Processors are installed out of order.
Contact your service representative to
replace the CPU.
0B28
Unsupported CPU detected on CPU Socket. Contact your service representative to
request the maintenance.
0B30
FAN1 Alarm occurred.
0B31
FAN2 Alarm occurred.
0B32
FAN3 Alarm occurred.
Cooling fan may be failed or clogged with
dust. Contact your service representative
to replace the fan.
0B42
Resource Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B50
Processor #1 with error taken off line.
0B5F
Forced to use Processor with error
Because an error is detected in CPU, the
system is forcibly started. Contact your
service representative.
0B60
DIMM #1 has been disabled
0B61
DIMM #2 has been disabled
0B62
DIMM #3 has been disabled
0B63
DIMM #4 has been disabled
0B6F
DIMM with error is enabled.
Contact your service representative.
0B70
The error occurred during temperature
sensor reading.
0B71
System Temperature out of the range.
Cooling fan may be failed or clogged with
dust. Contact your service representative
to replace the fan.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC Core Hardware failure.
0B83
BMC IBF or OBF check failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8A
BMC SEL area full.
Run SETUP and select [Server] - [Event
Log Configuration] - [Clear All Error Logs]
and press
Enter
to clear event logs.
Summary of Contents for N8100-1573F
Page 16: ...x This page is intentionally left blank...
Page 19: ...Notes on Using Your Server 1 3 3 5 inch Disk Model FRONT REAR...
Page 126: ...4 50 Configuring Your Server This page is intentionally left blank...
Page 296: ...A 2 Specifications This page is intentionally left blank...
Page 304: ...C 2 IRQ This page is intentionally left blank...
Page 333: ...Installing Windows Server 2008 D 29 4 Activate Windows The Windows activation is complete...
Page 390: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 394: ...H 4 Product Configuration Record Table This page is intentionally left blank...