1. Error Message
Express5800/R120d-1E, R120d-2E Maintenance Guide
137
Chapter 3 Appendix
[Recommended action]
Restart the server.
If it does not resolve your problem, contact your sales representative.
C201: Memory Configuration change is detected.
[Description]
The memory configuration has been changed since the previous startup.
[Recommended action]
When
Server
→
Check previous System Config
is in SETUP, this message appears if the memory
configuration was changed since the previous boot. If this message appears even when no configuration change
has been made, contact your sales representative.
C202: The error occurred during CPU configuration check.
[Description]
The CPU configuration data could not be acquired.
[Recommended action]
Restart the server.
If it does not resolve your problem, contact your sales representative.
C203: CPU Configuration change is detected.
[Description]
The CPU configuration has been changed since the previous startup.
[Recommended action]
When
Server
→
Check previous System Config
is in SETUP, this message appears if the CPU configuration
was changed since the previous boot. If this message appears even when no configuration change has been
made, contact your sales representative.
C300: Out-of-band setup configuration failure
[Description]
An error was detected while accessing BMC Mezzanine card.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
C301: SDR mismatch error.
[Description]
Inconsistency between hardware configuration and sensor data record was detected.
[Recommended action]